My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FLOOD
>
23390
>
4400 - Solid Waste Program
>
PR0505566
>
COMPLIANCE INFO_2006-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/3/2025 3:51:28 PM
Creation date
7/3/2020 11:10:47 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2007
RECORD_ID
PR0505566
PE
4443 - SW COMPOST SITE - MONTHLY INSPECTION
FACILITY_ID
FA0005674
FACILITY_NAME
OM SCOTT & SONS/HYPONEX CORP
STREET_NUMBER
23390
Direction
E
STREET_NAME
FLOOD
STREET_TYPE
RD
City
LINDEN
Zip
95236
APN
09310017
CURRENT_STATUS
Active, billable
SITE_LOCATION
23390 E FLOOD RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\cfield
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4443_PR0505566_23390 E FLOOD_2006-2007.tif
Site Address
23390 E FLOOD RD LINDEN 95236
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
373
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
January 23, 2008 Lab ID : STK0751018 <br /> Scotts Hyponex Corporation Customer : 3-12203 <br /> Quality Control -Inorganic <br /> Constituent Method Dat Type Units Conc. QC Data DQO Note <br /> Metals <br /> Nickel 2003 12/03/2007:212460 CCB ppm -0.00002 0.01 <br /> CCV ppm 1.000 99.4% 90-110 <br /> CCB ppm 0.0002 f 0.01 <br /> 3050 11/30/2007:211589 Blank mg/kg ND <0.5 <br /> L.CS mg/kg 40.00 107% 85-115 <br /> MS mg/kg 40.00 118% 75-125 <br /> MSD mg/kg 40.00 235% 75-125 435 <br /> MSRPD 40.00 65.9% :520 435 <br /> Selenium 200.7 12/04/2007:212465 CCV ppm 1.000 99.5% 90-110 <br /> CCB ppm 0.0007 0.01 <br /> CCV ppm 1.000 98.4% 90-110 <br /> CCB I ppm 0.0008 1 0.01 <br /> 3050 11/3((2007:211589 Blank mg/kg ND <0S <br /> L.CS mg/kg 40.00 101% 85-115 <br /> MS mg/kg 40.00 77.6% 75-125 <br /> MSD mg/kg 40.00 86.6% 75-125 <br /> MSRPD mgtkg 40.00 10.9% :520 <br /> Zinc 200.7 12tO3/2007:212460 CCV ppm 1.000 97.5% 90-110 <br /> CCB ppm -.000007 0.02 <br /> CCV ppm 1.000 98.7% 90-110 <br /> CCB p2m 1 0.0003 0.02 <br /> 3050 11/30/2007:211589 Blank mg/kg ND <1 <br /> L.CS mg/kg 100.0 110% 85-115 <br /> MS mg/kg 100.0 85.2% 75-125 <br /> MSD mg/kg 100.0 95.0% 75-125 <br /> MSRPD mgtkg 40.00 10.7% <_20 <br /> Wet Chem <br /> %Solids 2540E 11/2((2007:211302 Blank % ND <0.1 <br /> Dun 1.3% 23.9 <br /> Definition <br /> CCV :Continuing Calibration Verification- Analyzed to verify the instrument calibration is within criteria. <br /> CCB :Continuing Calibration Blank-Analyzed to verify the instrument baseline is within criteria. <br /> Blank :Method Blank-Prepared to verify that the preparation process is not contributing contamination to the samples. <br /> L.CS :Laboratory Control Standard/Sample-Prepared to verify that the preparation process is not affecting analyte recovery. <br /> MS Matrix Spikes-A random sample is spiked with a known amount of analyte. The recoveries are an indication of how that sample <br /> matrix affects analyte recovery. <br /> MSD :Matrix Spike Duplicate of MS/MSD pair-A ran sample duplicate is spiked with a known amount of analyted. The <br /> recoveries are an indication of how that sample matrix affects analyte recovery. <br /> Dup :Duplicate Sample-A random sample with each batch is prepared and analyzed in duplicate. The relative percent difference is an <br /> indication of precision for the preparation and analysis. <br /> MSRPD :MS/MSD Relative Percent Difference(RPD)-The MS relative percent difference is an indication of precision for the preparation <br /> and analysis. <br /> ND :Non-detect-Result was below the DQO listed for the analyte. <br /> DQO :Data Quality Objective-This is the criteria against which the quality control data is compared. <br /> Expiaination <br /> 435 :S le matrix MM be affecft this an!!)Le. Data was ted based on the LCS or CCV recovery. <br /> STKO751018:Quality Control Page 2 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.