COMPLIANCE INFO_1987-2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LINCOLN
>
401
>
4400 - Solid Waste Program
>
PR0440012
>
COMPLIANCE INFO_1987-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/24/2021 2:05:04 PM
Creation date
7/3/2020 11:15:02 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
1987-2005
RECORD_ID
PR0440012
PE
4445
FACILITY_ID
FA0002420
FACILITY_NAME
INDEPENDENT TRUCKING
STREET_NUMBER
401
Direction
S
STREET_NAME
LINCOLN
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
14703003
CURRENT_STATUS
02
SITE_LOCATION
401 S LINCOLN ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\sfrench
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4445_PR0440012_401 S LINCOLN_1987-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
653
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I COMM&N HAZARDS III EXIT REQUIREMEtWAYSAISLES,STAIRS&CORRIDORS) <br /> 1. STORAGE 1. MAINTENANCE OF EX <br /> -a. 12.106(d) Remove storage from exits,aisles,corridors -a. 12.104(b) Remove all other locks or latches from doors and <br /> and on or under stairs replace with panic hardware <br /> -b. 11.203(b) Arrange storage in an orderly manner and provide -b. 12.103(a) Remove all obstructions from exits,aisles, <br /> for exiting and fire department access corridors and stairways <br /> -c. 81.105 Reduce storage to 18"below level of -c. 12.104(a) Unlock all exit doors during business hours <br /> sprinklers(36"for storage over 12'high) _d. 12.113(a) Provide lighting for exit ways <br /> _d. 11.203(b) Reduce storage height to at least two(2)feet -e. 12.101 Maintain exit doors,stairs,etc.in good repair <br /> below ceiling -I. T24.2-3318 Post approved sign"THIS DOOR MUST <br /> 2. HOUSEKEEPING(INTERIOR/EXTERIOR) REMAIN UNLOCKED WHENEVER THE PUBLIC <br /> IS PRESENT." <br /> -a. 10.208 Post a visible street address min 3"letters -g. 25.114(a) Post occupant load sign <br /> -b. 11.201(b) Store rubbish in closed container -h. 25.114(c) Maintain occupant load at or below posted limits <br /> -c. 11.201(b) Remove or store waste material and oily rags -i. 12.114(a) Provide exit signs to indicate egress and/or <br /> in closed metal containers direction of egress <br /> -d. 11.404(d) . Provide 30"clearance between heat producing -j. 12.114(d) Provide lighting for exit sign(s) <br /> appliances and combustible material k. 12.101 Provide additional exit(s) <br /> -e. 11.203(c) Remove combustible storage from heater area or room -I. 12.101 Change swing of door(s) <br /> - <br /> I. 30.105(a) Provide an approved dust collecting device <br /> - IV FIRE PROTECTION EQUIPMENT AND ACCESS <br /> g. 11.201(a&b) Remove waste,trash,or weeds <br /> 1. FIRE PROTECTION INSTALLATIONS <br /> 3. SMOKING AND OPEN FLAMES <br /> _a. 10.314(e) Service and tag hood and duct extinguishing system <br /> -a. 13.101 Post and enforce"No Smoking"signs semi-annually and after each use <br /> -b. 13.101 Provide ash trays where smoking is permitted -b. 10.302(a) Extinguishing systems or appliances shall be <br /> maintained in an operative condition at all times <br /> 4. GAS _c. 10.307 Provide and maintain an approved smoke <br /> _a. 11.404(b) Gas shut-off to be installed within three(3)feet detector for each living unit <br /> of appliance and be readily accessible -d. 10.314(e) Clean grease filters over cooking appliance <br /> -b. 11.413 Provide protection for gas meter(s) _e. 10.302(a) Remove decorations or other attachments from <br /> _c. 3.101 Indicate individual unit numbers on meter banks sprinkler piping <br /> -I. 10.302(a) Provide a cap for fire department connection <br /> 5. ELECTRICAL -g. 10.302(a) Identify sprinkler valves and secure in open <br /> -a. 85.106(a) Discontinue use of extension cords in lieu of position <br /> permanent wiring -h. 10.302(a) Provide spare sprinklerheads(6 minimum)and <br /> -b. 85.106(c) Remove extension cords running through openings sprinkler wrench <br /> or attached in series -i. 10.302(a) Replace damaged,corroded,or painted <br /> _c. 85.106(c) Remove extension cords placed under rugs, sprinkler heads <br /> furniture or where subject to damage -j. 10.302(a) Maintain access to,and operation of fire <br /> -d. 85.104 Maintain wiring in good condition and protect protection appliances <br /> from damage -k. 10.309 Provide central station supervision of fixed <br /> fire protection system <br /> -e. 85.104 Provide cover plates <br /> _f. 85.104 Grounded-outlet required -1. T-19.904 Quarterly sprinkler inspection required, <br /> maintain records <br /> -g. 85.104 Provide covers for unused openings in <br /> electrical panel boxes -m. SMC4-008(b)Quarterly fire alarm inspection required, <br /> maintain records <br /> h. 85.104 Identify breakers in panel box -n. T-19.904 Five year service required <br /> -i. 85.104 Replace all damaged/spliced electrical cords COMPLIANCE DATE <br /> _j. 85.108 Electrical Panel and equipment shall have a 2. FIRE EXTINGUISHERS <br /> minimum of 30"clearance <br /> -k. 85.107 Discontinue use of multi-plug adaptors -a. 10.301(a) Provide extinguisher(s)with a minimum <br /> rating of 2A-10B:C <br /> 11 SPECIAL HAZARDS -b. 10.301(a) Provide a extinguisher for <br /> 1. PERMITS <br /> _c. 10.302(a) Mount extinguisher(s)where readily accessible,with <br /> - 4.101 Obtain permit(s)or discontinue top not to exceed five(5)feet from floor level <br /> -d. 10.302(a) Post sign(s)indicating location of <br /> extinguisher(s)not readily visible <br /> 2. FLAMMABLE AND COMBUSTIBLE LIQUIDS _e. 10.302(a) Service and tag each extinguisher annually and <br /> after each use <br /> -a. 79.201(g) Provide approved cabinet or inside storage room <br /> for all flammable liquids 3. OCCUPANCY AND AREA SEPARATIONS <br /> -b. 79.104(a) Provide approved safety cans for dispensing <br /> flammable liquids r:.'t;;:i -a. 10.402(b) Remove obstruction(s)and/or alterations to <br /> fire assemblies. <br /> -c. 79.802(b) Flammable liquicls.shall be dispensed by approved _b. 11.406 Keep attic access and scuttle openings closed <br /> pumps taking suction tprough the top of the container <br /> -d. 79.802(d) Provide approved bonding/grounding when -c. 10.402 Maintain occupancy separations,and area <br /> dispensing flammable liquids separation walls when damaged,altered,removed. <br /> or improperly installed <br /> -e. 79.103 Reduce Class I liquids(Gasoline,etc.)to less -d• 10.402(c) A sign with a minimum of 1-inch letters is <br /> than five(5)gallons inside and ten(10)gallons <br /> outside without a permit required on or near the fire door(s)to read <br /> "FIRE DOOR-DO NOT OBSTRUCT" <br /> -f. 79.111 Discontinue use of Class I liquids for cleaning <br /> -g. 79.201(d) Store flammable liquids away from exit ways 4. FIRE DEPARTMENT ACCESS <br /> 3. HAZARDOUS MATERIALS -a. 10.207(e) Keep 20'access road unobstructed <br /> -b. S.M.C.10-024.6(c) Keep fire lane clear of parked vehicles <br /> -a. 80.109 Provide approved cabinet o_r inside storage room -c. 10.209 Provide KNOXBOX for fire department access <br /> for all hazardous materials <br /> -b. 80.103(f) Mark.•all fixed storage facilities in accordance -d. 10.209 Provide proper keys for KNOXBOX <br /> ,With.NFPA 704M -e. 81.109(b) Provide a sign w/one inch,letters on <br /> c. 80.103(hj ProM <br /> vide aterial Safety.Data sheet for required access doors.Inside❑ Outside❑ <br /> _ d. 74.107 Sepurq and identify compressed gas cylinders <br /> 74.104 with name of product <br /> ORDER TO COMPLY: A REASONABLE DEGREE OF FIRE/LIFE SAFETY EXISTS AT THIS TIME r <br /> DAT ' <br /> As such conditions are contrary to law, you are hereby required to correct above indicated conditions immediately upon receipt of this notice. An inspection <br /> to determine whether or not you have complied with this notice will be conducted within days. <br /> Failure to comply with the foregoing'order'before the'date of such reinspection may render you liable to the penalties provided by law for such violations. <br /> REINSPECTION DATE SIGNATURE OF RESPONSIBLE PARTY <br /> NOTE: SMOKE DETECTORS ARE REQUIRED BYLAW IN EVERY RESIDENCE AND LIVING UNIT. <br /> DISTRIBUTION: WHITE-RESPONSIBLE PARTY CANARY-FILE <br /> FD 63 REVISED 10/87 <br />