My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2010-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOVELACE
>
2323
>
4400 - Solid Waste Program
>
PR0440013
>
ARCHIVED REPORTS_2010-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/13/2021 4:06:43 PM
Creation date
7/3/2020 11:15:51 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2010-2015
RECORD_ID
PR0440013
PE
4445
FACILITY_ID
FA0001434
FACILITY_NAME
LOVELACE TRANSFER STATION
STREET_NUMBER
2323
STREET_NAME
LOVELACE
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20406020
CURRENT_STATUS
01
SITE_LOCATION
2323 LOVELACE RD
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4445_PR0440013_2323 LOVELACE_2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
514
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- Used oil must be stored in tanks or contain- <br />ers in good condition. Tanks and containers must <br />be made of non -earthen, non -absorbing, rust -re- <br />sistant material such as steel or oil -resistant plastic, <br />and have adequate structural support to contain the <br />used oil. "Good condition" means no severe rust- <br />ing, no apparent structural defects or deterioration, <br />and no leaking. All tanks and containers must have <br />tight -fitting lids that are kept closed except when <br />used oil is being added or removed. Regular <br />inspections and routine maintenance of all stor- <br />age tanks and containers are required. Faulty <br />tanks and containers must be repaired or replaced. <br />• Secondary containment for storage tanks is <br />required. Secondary containment is a backup <br />containment system designed to prevent the release <br />and migration of wastes or accumulated liquids out <br />of a storage tank or a storage tank system Examples <br />of secondary containment systems include: an im- <br />pervious barrier such as a liner, a vault, a double - <br />walled tank or an impervious bermed area. <br />• Aboveground storage tanks and containers <br />accumulating used oil, and fill pipes used to <br />transfer used oil into underground storage tanks <br />must be labeled with the words "USED OIL - <br />HAZARDOUS WASTE," the initial date of ac- <br />cumulation, and the name and address of the <br />generator. For shipping, containers must also <br />be labeled with the following: <br />• The statement: "Hazardous Waste - State <br />and Federal Law Prohibit Improper Dis- <br />posal. If found, contact the nearest police <br />or public safety authority, the U.S. Envi- <br />ronmental Protection Agency or the Cali- <br />fornia Department of Toxic Substances <br />Control." <br />- The generator's name and address. <br />• The proper Department of Transportation <br />(DOT) shipping name and the generator's <br />identification number. <br />- The Uniform Hazardous Waste Manifest <br />riffill <br />- The shipping identification number. <br />• Additional requirements for used oil genera- <br />tors are contained in the HSC and 22 CCR pro- <br />visions cited at the beginning of this fact sheet. <br />The Rebuttable Presumption <br />(Total Halogens Determination) <br />The Used Oil Handler is Required to Make a <br />Total Halogens Determination: <br />Testing <br />or <br />Application or <br />Knowledge <br />1'000 pom <br />O D 'otal Halogens <br />Halogens I ITotal T'Hot Load" } }IW <br />Solely <br />DIY! <br />UNLESS: <br />Demonstrate <br />d 0-1 <br />Us- OiI <br />That The Used <br />Oil Was Not <br />Miall rirm tsYV <br />Solely Metal <br />USED <br />Working Oils <br />Solely <br />OIL <br />CFC>Rafngeration <br />Oils <br />USED <br />USED <br />OIL <br />OIL <br />USED <br />OIL <br />Used oil handlers (e.g., generators, used oil col- <br />lection centers, transporters and used oil recy- <br />cling facilities) are required to determine <br />whether the total halogen content of each used <br />oil shipment exceeds 1,000 ppm halogens. Used <br />oil determined to contain more than 1,000 ppm <br />total halogens is presumed to have been mixed <br />with halogenated hazardous waste. Used oil <br />containing more than 1,000 ppm total halogens <br />must be managed as a Resource Conservation <br />and Recovery Act (RCRA) hazardous waste un- <br />less the used oil can be demonstrated not to have <br />been mixed with halogenated hazardous waste <br />(i.e., unless the presumption is rebutted). This <br />requirement is called the "rebuttable presumption." <br />- 3 - DTSC Used Oil and Used Oil Filters Fact Sheet <br />
The URL can be used to link to this page
Your browser does not support the video tag.