My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2014
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0517379
>
ARCHIVED REPORTS_2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2020 11:24:49 AM
Creation date
7/3/2020 11:19:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2014
RECORD_ID
PR0517379
PE
4466
FACILITY_ID
FA0007101
FACILITY_NAME
FORWARD INC LANDFILL
STREET_NUMBER
9999
Direction
S
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106003
CURRENT_STATUS
02
SITE_LOCATION
9999 S AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4466_PR0517379_9999 S AUSTIN_2014.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
181
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• Observe sample cutting. <br /> • Mark each specimen and sample with an identifying number that contains the seam <br /> number,destructive sample test number,welder, and date and time welded. <br /> • Record sample locations on the panel layout drawing and panel-seam logs <br /> • Record the sample locations,weather conditions,and reasons samples were taken(e.g., <br /> random sample, visual appearance, result of a previous failure, etc.) on the destructive <br /> seam test form. <br /> At each location,obtain two seam specimens that are 42-inches apart. The specimens should be f- <br /> inch wide and 12-inches long with the weld centered across the length of the specimen. The <br /> Geosynthetics Contractor must test these samples to failure in the field using a tensiometer capable <br /> of quantitatively measuring shear and peel strengths.For double wedge welding,the Geosynthetics <br /> Contractor must test both welds. The QA/QC Inspector will observe the tests. Geomembrane seam <br /> specimens pass when the break is a ductile FTB. A film tearing bond means the test specimen <br /> breaks at the edge of the outside of the seam, but not in the seam. In addition, the seam strength <br /> must meet the specified values. <br /> If one or both of the 1-inch specimens fails in either peel or shear,the Geosynthetics Contractor can, <br /> at his discretion: (1)reconstruct the entire seam between passed test locations; or(2)take another <br /> test sample 10 feet from the point of the failed test and repeat this procedure. If the second test <br /> passes,the Geosynthetics Contractor can either reconstruct or cap strip the seam between the two <br /> passed test locations. If subsequent tests fail,the sampling and testing procedure is repeated,until <br /> the length of the poor quality seam is established. Repeated failures indicate that either the seaming <br /> equipment or operator is not performing properly, and appropriate corrective action must be taken <br /> immediately. <br /> Once the field tests specimens have passed a sample must be recovered for laboratory testing from <br /> between the passing field specimen locations. The sample must be 42-inches long and 12-inches <br /> wide,with the weld centered along the length of the sample. The sample must be divided into three <br /> sections: one 12-inch by 12-inch section for the Geosynthetics Contractor, one 12-inch by 18-inch <br /> section for laboratory testing, and one 12-inch by 12-inch for the Owner to archive. Record the <br /> results of field testing on the destructive seam tests form, the panel/seam log. <br /> Third Party Laboratory Testing. All CQA destructive samples must be shipped to the <br /> testing Iaboratory to verify seam quality. The laboratory will test five specimens from <br /> each sample in each method used. Minimum test values are presented in the <br /> specifications. The testing laboratory must provide test results within 24 hours, in <br /> writing or via telephone,to the QA/QC Manager with certified test results to be provided <br /> within 5 days. <br /> The QA/QC Manager must immediately notify the Construction Manager and Geosynthetics <br /> Page 28 <br />
The URL can be used to link to this page
Your browser does not support the video tag.