My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PR0440063_1990-2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VIA NICOLO
>
17950
>
4400 - Solid Waste Program
>
PR0440063
>
COMPLIANCE INFO_PR0440063_1990-2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/12/2021 3:46:00 PM
Creation date
7/3/2020 11:20:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PR0440063_1990-2019
RECORD_ID
PR0440063
PE
4467
FACILITY_ID
FA0002971
FACILITY_NAME
MUSCO FAMILY OLIVE CO
STREET_NUMBER
17950
Direction
W
STREET_NAME
VIA NICOLO
City
TRACY
Zip
95377
APN
20911032
CURRENT_STATUS
02
SITE_LOCATION
17950 W VIA NICOLO
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\sfrench
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4467_PR0440063_17950 W VIA NICOLO_.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
239
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING AND REPORTING PROGRAM _5_ <br /> MUSCO OLIVE PRODUCTS, INC. <br /> CLASS II SURFACE IMPOUNDMENTS <br /> SAN JOAQUIN COUNTY <br /> LCRS MONITORING <br /> All LCRS sumps shall be inspected quarterly for leakage. Upon detection of leakage in a . <br /> previously dry LCRS, the Discharger shall immediately collect a grab sample of the leakage and <br /> shall continue to grab sample the leakage at the following frequencies thereafter. The LCRS shall <br /> be sampled and analyzed for the following: <br /> Report in Sampling <br /> Parameter/Constituent Units of Frequency <br /> Flow Rate gallons/month Monthly <br /> Specific Conductance µmhos/cm Quarterly <br /> (field and lab) <br /> pH(field and lab) number Quarterly <br /> Total Dissolved Solids mg/1 Quarterly <br /> Chloride mg/1 Quarterly <br /> Sulfate mg/l Quarterly <br /> Nitrate-Nitrogen mg/l Quarterly <br /> C.O.D. mg/1 Quarterly <br /> Total Hardness mg/l Quarterly <br /> General Mineralsl mg/l Annually <br /> All LCRSs shall be tested annually to demonstrate operation in conformance with waste <br /> discharge requirements.The results of these tests shall be reported to the Board and shall <br /> include comparison with earlier tests made under comparable conditions. <br /> SURFACE WATER MONITORING <br /> Surface water samples shall be sampled at upstream and downstream stations during the first <br /> storm of the rainy season which produces significant flow and quarterly when water is present. <br /> Grab samples shall be analyzed for the following: <br /> Report in Sampling <br /> Parameter/Constituent Units of Frequency <br /> Flow Rate gallons/month Monthly <br /> Specific Conductance (field) µmhos/cm Quarterly <br /> pH(field) number Quarterly <br /> Temperature(field) 'C Quarterly <br /> Suspended Solids mg/1 Quarterly <br /> Chemical Oxygen Demand(COD) mg/1 Quarterly <br /> Chloride mg/1 Quarterly <br /> Sulfate mg/1 Quarterly <br /> Nitrate-Nitrogen mg/l Quarterly <br /> Total Dissolved Solids mg/1 Quarterly <br /> General Minerals t mg/1 Annually <br /> ---- I General-Minerals include:Ca Mg,K;HCO3;-SO4 --- <br />
The URL can be used to link to this page
Your browser does not support the video tag.