My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PR0440063_1990-2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VIA NICOLO
>
17950
>
4400 - Solid Waste Program
>
PR0440063
>
COMPLIANCE INFO_PR0440063_1990-2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/12/2021 3:46:00 PM
Creation date
7/3/2020 11:20:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PR0440063_1990-2019
RECORD_ID
PR0440063
PE
4467
FACILITY_ID
FA0002971
FACILITY_NAME
MUSCO FAMILY OLIVE CO
STREET_NUMBER
17950
Direction
W
STREET_NAME
VIA NICOLO
City
TRACY
Zip
95377
APN
20911032
CURRENT_STATUS
02
SITE_LOCATION
17950 W VIA NICOLO
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\sfrench
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4467_PR0440063_17950 W VIA NICOLO_.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
239
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoring Report Compliance Checklist 3 <br /> t <br /> Discharges Regulated by Title 27 and/or Part 258 <br /> Reference Parameter Yes No N/A RWQCB <br /> Reviewer Comment <br /> WDRs/MRP/ Groundwater Monitoring X <br /> Standard <br /> Provisions 1. Are all groundwater Field <br /> (1993,1997,2000, Parameters Monitoring Parameter, <br /> 2003) and COCs(if required)sampled <br /> and analyzed? <br /> in. Have any groundwater X WQPS have not been established. In general, <br /> concentration limits been TDS,chloride,and sodium exceed the <br /> exceeded? If yes, identify in agricultural water quality goals of 450, 106, <br /> comments. and 69 mg/L in most shallow zone wells. <br /> n. Is there a description and X Computer generated contour map constructed <br /> graphical presentation of over an aerial photo. No reference to Model <br /> groundwater flow direction and used. Figure in general is hard to read. <br /> gradient? Shallow zone and deep zone contours should <br /> be constructed on separate sheets. <br /> o. Monitoring Wells: Is there a X <br /> description,method,and time of <br /> water level measurement and well <br /> recovery time? <br /> p. Purging: Is there a description of X <br /> the purging method,purge pump <br /> and its placement,and field <br /> parameters? <br /> WDRs Semiannual/Annual Monitoring <br /> Standard Report(when applicable) <br /> Provisions <br /> (1993,1997,2000, q. Are all monitoring parameters and <br /> 2003) COCs graphed so as to show <br /> historical trends at each <br /> Monitoring Point and Background <br /> Monitoring Point? <br /> r. Is all monitoring analytical data <br /> obtained in the last year presented <br /> in tabular form,as well as on a <br /> diskette or CD? <br /> s. Is there a comprehensive <br /> discussion of the compliance <br /> record and the result of any <br /> corrective actions? <br /> t. Is there a map showing the area <br /> and elevations in which filling has <br /> been completed during the past <br /> year and comparison to final <br /> closure contours? <br />
The URL can be used to link to this page
Your browser does not support the video tag.