COMPLIANCE INFO_PR0440063_1990-2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VIA NICOLO
>
17950
>
4400 - Solid Waste Program
>
PR0440063
>
COMPLIANCE INFO_PR0440063_1990-2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/12/2021 3:46:00 PM
Creation date
7/3/2020 11:20:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PR0440063_1990-2019
RECORD_ID
PR0440063
PE
4467
FACILITY_ID
FA0002971
FACILITY_NAME
MUSCO FAMILY OLIVE CO
STREET_NUMBER
17950
Direction
W
STREET_NAME
VIA NICOLO
City
TRACY
Zip
95377
APN
20911032
CURRENT_STATUS
02
SITE_LOCATION
17950 W VIA NICOLO
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\sfrench
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4467_PR0440063_17950 W VIA NICOLO_.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
239
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Musco Family Olive Compan* - 2 - 6 March 2008 <br /> The report evaluates the newly installed wells and attempts to categorize the wells into several <br /> water bearing units identified as: the shallow, intermediate, and deep zones beneath the site. <br /> The evaluation in Table 6 of the report is based on chemical concentrations and the Phase I <br /> summary proposes that high salinity groundwater found in wells MW-2 and MW-25 is mixing <br /> with groundwater encountered approximately 60 to 70 feet above it. The report does not <br /> evaluate the application or storage of process wastewater and its chemical contribution to <br /> groundwater. <br /> The report proposes the Phase II Groundwater Investigation Work Plan will continue to <br /> investigate several hypotheses, further develop the site conceptual model, and determine the <br /> water quality protection standard for the site. The work plan proposes to install monitoring <br /> wells in three study areas shown in the table below. Additional staff recommendations are <br /> also included in the table below: <br /> Study Area Well Type Well Objective <br /> Area 1 —Offsite Well Cluster#1 Shallow/Deep well— Compare offsite GW quality <br /> southeast of site with onsite GW quality <br /> Well Cluster#2 Shallow/Deep well— Compare offsite GW quality <br /> northeast of site with onsite GW quality. Staff <br /> requests Musco move the <br /> well cluster southeast behind <br /> the Safeway Distribution <br /> Center. <br /> Canal Influence Well Shallow well— Evaluate potential impact of <br /> northeast of Well Cluster#2 leakage from Cal. Aqueduct. <br /> Staff requests Musco also <br /> drill a deep well at this <br /> location. <br /> Area 2 - Uplands Well Cluster#3—First Encountered GW Assess DTW; GW quality; <br /> well northeast of 84 M gallon reservoir and supplement stratigraphic <br /> between MW-16 and MW-4 data from Boring#4. <br /> Soil Boring#4 First Encountered GW— Provide lithologic data <br /> 600 feet north of former 1 M gallon pond between MW-4 and MW-8. <br /> Staff requests Musco build a <br /> well at first encountered <br /> water. <br /> Area 3—Lowland Well Cluster#5 First Encountered GW Expected deep zone well. <br /> 900 feet northeast of well MW-7 Assess deep GW quality and <br /> elevation <br /> Supplemental Wells— High Salinity Deep Wells—PDW1 through Water quality and gradient <br /> Upgradient PDW3 data; potential mixing of <br /> offsite/Swale deep water and shallow GW. <br /> Staff requests Musco drill <br /> PDW#4 in the vicinity of <br /> MIN-22. <br />
The URL can be used to link to this page
Your browser does not support the video tag.