Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> MONITORING SYSTEM CERTIFICATION FORM (Page 1 of 6) <br /> This form must be used to document testing and servicing of underground storage tank(UST) monitoring equipment. A copy <br /> of this form must be provided to the UST owner or operator. The owner or operator must submit a copy of this form to the local <br /> agency regulating the USTs within 30 days of the date of the monitoring system certification. <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Monitoring System Certification <br /> 10156819 6/9/20 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) Building# <br /> Safeway#2600 <br /> Business Site Address City ZIP Code <br /> 1987 W 11th St. Tracy 195376 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of Company Performing the Certification Phone# <br /> Service Station Systems, Inc. (408)971-2445 <br /> Mailing Address <br /> 680 Quinn Ave.,San Jose 95112 <br /> Name of UST Service Technician Performing the Certification (Print as shown on the ICC Certification) <br /> Kristopher Bell <br /> Contractor/Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> 485184 8833000 10/29/2021 <br /> Monitoring System Training and Certifications List all applicable certifications. Ex iration Date <br /> Veeder Root TLS 3XX B33709 3/25/2021 <br /> Vaporless Manufacturing Inc#3225/1324 11/1/2020 <br /> Red Jacket#B33709 6/25/2020 <br /> FE PETRO#1004933708 7/16/2020 <br /> III. RESULTS OF TESTING/SERVICING <br /> Indicate and attach the following reports if the monitoring equipment is capable of generating either. <br /> © MonitoringSystem Set-upY N NA <br /> �Alarm Histo Report <br /> Was any monitoring equipment replaced? <br /> (If"Yes,"identify the specific devices replaced and list the manufacturer and model for all replacement parts in section IV below.) <br /> Was damage, debris, or liquid found inside any secondary containment systems? <br /> (If"Yes,"describe what was found in section IV below.) <br /> Is all monitoring equipment operational per manufacturer's specifications? <br /> (If"No."describe why in section IV below.) <br /> IV. COMMENTS <br /> If directed to use this section,describe how and when the issues were or will be corrected. <br /> Replaced Bad Annular Sensor for the Premium-Diesel Split Tank-Retested&Passed. <br /> RECEIVE ® <br /> JUL 7 2020 <br /> ENVIRONMENTAL HEALTH <br /> DERARTPOENT <br /> V. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> I hereby certify that the equipment identified in this document was inspected/serviced in accordance with California Code of <br /> Regulations,Title 23, Division 3, Chapter 16,Section 2638 and all information contained herein is true and accurate. Attached to <br /> this certification is information (e.g., manufacturers' checklists, monitoring system set-up, alarm history report, etc.) necessary <br /> to verify that this information and the site plan showing the layout of UST system is complete and accurate. <br /> UST Service Technician Signature <br /> CERS=California Environmental Reporting System,ID=Identification,ICC=International Code Council,Y=Yes,N=No,NA=Not Applicable <br />