My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1987
>
2300 - Underground Storage Tank Program
>
PR0517565
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:33 AM
Creation date
7/6/2020 1:21:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0517565
PE
2361
FACILITY_ID
FA0013503
FACILITY_NAME
SAFEWAY FUEL CENTER #2600
STREET_NUMBER
1987
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
1987 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
171
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Recommended Practices for the Testing and Verification of Spill,Overfill,Leak Detection and Secondary Containment Equipment at UST Facilities <br /> APPENDIX A-2 <br /> ZCL I XERXES® TRUCHEK® <br /> making a lasting difference DATA LOG <br /> Fill out the site location,tank information and test boxes below.Be sure to choose the correct test box according to the <br /> diameter of the tank being tested.Follow the test procedures on the other side of this form.A separate test form is needed <br /> for every tank.For additional copies of the form,contact the Customer Service Representative at the Xerxes manufacturing <br /> facility nearest you.(See back cover for information.) <br /> SITE LOCATION AND TANK INFORMATION <br /> Site Location: Tank Information: <br /> Address: _ Nominal Gallons: <br /> Diameter: <br /> Phone: Approximate Standpipe Length: <br /> Contact Name: - _ Product Type: _ <br /> Test Date: _. Person Performing Test: <br /> •• • •• •• DOUBLE-WALL TANKS <br /> 95% - 5% TEST 99% - 1% TEST <br /> 1 a. Start level(inches in standpipe) 1b.Start level(inches in standpipe) <br /> 2a. End level after 4 hours 2b. End level after 10 hours <br /> 3. Difference(subtract 2a from 1 a) = 3. Difference(subtract 2b from 1 b) _ <br /> 4. Calibration factor x .20 4.Calibration factor x .20 <br /> 5. Volume change = 5.Volume change = <br /> 6.Test hours _ 4 6.Test hours 10 <br /> 7. Gallons-per-hour loss = 7. Gallons-per-hour loss = <br /> (If 0.05 gallonsihour or less,tank passed.) (If 0.05 gallons/hour or less,tank passed.) <br /> Note:maximum allowable dispensing volume during test: Note:No product dispensing allowed. <br /> 8-foot-diameter tank-1,200 gallons maximum <br /> 6-foot-diameter tank-500 gallons maximum <br /> ,4-foot-diameter tank-300 gallons maximum <br /> 10-FOOT-DIAMETER DOUBLE-WALL <br /> 95% - 5%TEST 99% -1% TEST <br /> la. Start level(inches in standpipe) tb. Start level(inches in standpipe) <br /> 2a. End level after 6 hours 2b. End level after 10 hours <br /> 3. Difference(subtract 2a from 1 a) = 3. Difference(subtract 2b from 1 b) _ <br /> 4. Calibration factor x .30 4. Calibration factor x .30 <br /> S.Volume change = 5. Volume change <br /> 6.Test hours - 6 6.Test hours - 10 <br /> 7. Gallons-per-hour loss = 7. Gallons-per-hour loss = <br /> (If 0.05 gallons/hour or less,tank passed,) (If 0.05 gallons/hour or less,tank passed.) <br /> Note:Maximum allowable dispensing volume during test: Note:No product dispensing allowed. <br /> 10-foot-diameter tank-750 gallons maximum <br /> pei.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.