My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1987
>
2300 - Underground Storage Tank Program
>
PR0517565
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:33 AM
Creation date
7/6/2020 1:21:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0517565
PE
2361
FACILITY_ID
FA0013503
FACILITY_NAME
SAFEWAY FUEL CENTER #2600
STREET_NUMBER
1987
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
1987 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
171
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
rq-1y PERM 200-17 <br /> HYDROSTATICAPPENDIX C-3 <br /> SPILL BUCKET INTEGRITY TESTING OD <br /> SINGLE-AND DOOD <br /> Facility Name: Owner: <br /> Address: Address: <br /> City,State,Zip Code: City,State,Zip Code: <br /> Facility I.D.#: Phone#: <br /> Testing Company: Phone#: Date: <br /> This procedure is to test the leak integrity of single-and double-walled spill buckets.See PEI/RP1200 Section 6.2 for hydrostatic test <br /> method,Section 6.3 for single-walled vacuum test method and Section 6.4 for double-walled vacuum test method. <br /> Tank Number <br /> Product Stored <br /> Spill Bucket <br /> Capacity <br /> Manufacturer <br /> Construction ❑Single-walled ❑Single-walled ❑Single-walled ❑Single-walled ❑Single-walled ❑Single-walled <br /> ❑Double-walled ❑Double-walled ❑Double-walled ❑Double-walled ❑Double-walled ❑Double-walled <br /> Test Type ❑Hydrostatic ❑Hydrostatic ❑Hydrostatic ❑Hydrostatic ❑Hydrostatic ❑Hydrostatic <br /> ❑Vacuum ❑vacuum ❑Vacuum ❑Vacuum ❑Vacuum ❑Vacuum <br /> ❑Single-walled ❑Single-walled ❑Single-walled ❑Single-walled ❑Single-walled ❑Single-walled <br /> ❑Double-walled ❑Double-walled ❑Double-walled ❑Double-walled ❑Double-walled ❑Double-walled <br /> Spill Bucket Type ❑Product ❑Product ❑Product ❑Product ❑Product ❑Product <br /> ❑Vapor ❑Vapor ❑Vapor ❑Vapor ❑Vapor ❑Vapor <br /> Liquid and debris <br /> removed from ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No <br /> spill bucket?* <br /> Visual Inspection <br /> (No cracks,loose <br /> parts or separa- ❑Pass ❑Fail ❑Pass ❑Fail ❑Pass ❑Fail ❑Pass ❑Fail ❑Pass ❑Fail ❑Pass ❑Fail <br /> tion of the bucket <br /> from the fill pipe.) <br /> Tank riser cap ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No <br /> included in test? ❑NA ❑NA ❑NA ❑NA ❑NA ❑NA <br /> Drain valve []Yes ❑No ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No <br /> included in test? ❑NA ❑NA ❑NA ❑NA ❑NA ❑NA <br /> Starting Level <br /> Test Start Time <br /> Ending Level <br /> Test End Time <br /> Test Period <br /> Level Change <br /> Pass/fail criteria:Must pass visual Inspection.Hydrostatic:Water level drop of less than 1/8 inch;Vacuum single-walled only: <br /> Maintain at least 26 inches water column;Vacuum double-walled:maintain at least 12 inches water column. <br /> Test Results ❑Pass ❑Fail ❑Pass ❑Fail ❑Pass ❑Fail ❑Pass ❑Fail ❑Pass ❑Fail ❑Pass ❑Fail <br /> Comments: <br /> *All liquids and debris must be disposed of properly. <br /> Tester's Name(print) Tester's Signature <br /> 0 pei.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.