Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> SECONDARY CONTAINMENT TESTING REPORT FORM ( Page 1 of 6) <br /> Type of Action ❑ Installation Test ❑ Repair Test ❑ Six Month Test ® 36 Month Test <br /> I . FACILITY INFORMATION <br /> CERS ID Date of Secondary Containment Test <br /> 10156819 9/ 15/2020 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) <br /> Safeway #2600 <br /> Business Site Address City ZIP Code <br /> 1987 W. 11 th St. Tracy 95376 <br /> II . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Test (Print as shown on the ICC Certification) Phone # <br /> Michael McCarter (707 ) 545-5522 <br /> Contractor / Tank Tester License ; ICC Certification # ICC Certification Expiration Date <br /> Able Maintenance , Inc. - 312844 8819839 10/15/2021 <br /> III . SUMMARY OF SECONDARY CONTAINMENT TESTING RESULTS <br /> TANK ID : (By tank number, stored product, etc.) A 87 B 91 C Diesel D <br /> Tank Containment <br /> Tightness Test Result ® Pass ❑ Fail ❑ NA 0 Pass ❑ Fail ❑ NA 0 Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Product Piping Containment <br /> Tightness Test Result ❑ Pass m Fail ❑ NA ❑ Pass ® Fail ❑ NA ® Pass ❑ Fail ❑ NA ❑ Pass ® Fail ❑ NA <br /> Communication Test Result ❑ Pass 0 Fail ❑ NA ❑ Pass 21 Fail ❑ NA 0 Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Remote Fill Piping Containment <br /> Tightness Test Result ❑ Pass ❑ Fail 0 NA ❑ Pass ❑ Fail 0 NA ❑ Pass ❑ Fail 0 NA ❑ Pass ❑ Fail ❑ NA <br /> Communication Test Result ❑ Pass ❑ Fail ® NA ❑ Pass ❑ Fail ® NA ❑ Pass ❑ Fail m NA ❑ Pass ❑ Fail ❑ NA <br /> Vent Piping Containment <br /> Tightness Test Result ❑ Pass ❑ Fail 0 NA ❑ Pass ❑ Fail 0 NA ❑ Pass ❑ Fail 0 NA ❑ Pass ❑ Fail ❑ NA <br /> Communication Test Result ❑ Pass ❑ Fail 0 NA ❑ Pass ❑ Fail ® NA ❑ Pass ❑ Fail ® NA ❑ Pass ❑ Fail ❑ NA <br /> Vapor Recovery Piping Containment <br /> Tightness Test Result ❑ Pass ❑ Fail 0 NA ❑ Pass ❑ Fail 21 NA ❑ Pass ❑ Fail 0 NA ❑ Pass ❑ Fail ❑ NA <br /> Communication Test Result ❑ Pass ❑ Fail ® NA ❑ Pass ❑ Fail ® NA ❑ Pass ❑ Fail VI NA ❑ Pass ❑ Fail ❑ NA <br /> Turbine / Product Piping Sump <br /> Tightness Test Result ❑ Pass ® Fail ❑ NA ❑ Pass ® Fail ❑ NA ❑ Pass ® Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Fill Riser Sump <br /> Tightness Test Result 0 Pass ❑ Fail ❑ NA ❑ Pass 0 Fail ❑ NA 0 Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> PW <br /> VENT / TRANSITION SUMP ID : a b C d <br /> Tightness Test Result ❑ Pass ❑ Fail 0 NA ❑ Pass ❑ Fail 0 NA ❑ Pass ❑ Fail 0 NA ❑ Pass ❑ Fail ❑ NA <br /> UDC ID : <br /> 11 /2 23/4 35/6 47/8 <br /> Tightness Test Result ❑ Pass m Fail ❑ NA ❑ Pass ® Fail ❑ NA ❑ Pass m Fail ❑ NA ❑ Pass ® Fail ❑ NA <br /> UDC ID : 59/10 611 /12 713/ 14 815/ 16 <br /> Tightness Test Result ❑ Pass 0 Fail ❑ NA ❑ Pass ® Fail ❑ NA ❑ Pass 0 Fail ❑ NA ❑ Pass 0 Fail ❑ NA <br /> UDC ID : 917/18 jal019/20 11 12 <br /> Tightness Test Result ❑ Pass m Fail ❑ NA ❑ Pass ® Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> All items marked "Fail' or "NA " must be explained in their respective "COMMENTS " section. <br /> IV. CERTIFICATION BY UST SERVICE TECHNICIAN CON D4Crt11 G7,THI&PI ESTING, <br /> I hereby certify that the secondary containment was tested in accordance with California Code of Regulations , Title 23 , Division <br /> 3, Chapter 16 , Section 2637 and all the information contained herein is accurate. (� ( . i <br /> UST Service Technician Signature <br /> � : <br /> CERS = California Environmental Reporting System, ID = Identification, UST = Underground Storage Tank, ICC = Intemational Code Council NA -Not Appljcpble, UDC = Under- <br /> Dispenser Containment <br /> j <br />