My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
3400
>
2300 - Underground Storage Tank Program
>
PR0518738
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2022 1:20:33 PM
Creation date
7/6/2020 1:23:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0518738
PE
2361
FACILITY_ID
FA0014111
FACILITY_NAME
CHEVRON STATION #212470/2222*
STREET_NUMBER
3400
STREET_NAME
MACARTHUR
STREET_TYPE
DR
City
TRACY
Zip
95376
APN
21306016
CURRENT_STATUS
01
SITE_LOCATION
3400 MACARTHUR DR
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
165
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUNDSTORAGETANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM(Page 1 of 1) <br /> Type of Action r Installation Test r Repair Test r 36 Month Test <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection: <br /> 10184563 1 6/29/2020 <br /> Business Name (Same as Facility Name or DBA-Doing Business As.) <br /> Chevron 212470 <br /> Business Site Address City: Zip: <br /> 3400 N MacArthur Drive Tracy 95376 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Test(Print as shown on the ICC Certification.) Phone# <br /> Brent Bowen (800)800-4633 <br /> Contractor/Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> Class A General Engineering 743160 8211862 6/17/2021 <br /> Spill Container Testing Training and Certifications(List applicable certifications.) <br /> CA-Tightness Testing 14-1759 06/30/2020 Franklin Fueling-Phil-Tite EVR Ph 1 Systems 1004223708 01/05/2021 <br /> III. OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> WO Manufacturer Guidelines(Specify) Cow <br /> Test Method Used: r Industry Code or Engineering Standard (Specify) PEI RP 1200 <br /> r <br /> Engineered Method (Specify) <br /> Attach the testing procedures and all documentation required to determine the results. #of Attached Pages: <br /> 1 <br /> Tank ID: (By tank number, stored product, etc.) 91 87 dsl <br /> What is the tank inside diameter?(Inches) 117.38 in. 117.38 in. 117.38 in. <br /> Is the fill piping secondarily contained? r Yes r No r Yes r No r Yes r No r Yes r No <br /> Is the vent piping secondarily contained? r Yes r No r Yes r No r Yes r No r Yes r No <br /> Overfill Prevention Equipment Manufacturer(s) <br /> OPW OPW OPW <br /> W Shuts Off Flow r Shuts Off Flow f7 Shuts Off Flow r Shuts Off Flow <br /> when act <br /> What cthe overfill prevention equipment response r Restrict Flow r Restrict Flow r Restrict Flow r Restrict Flow <br /> activated?(Check all that apply.) r A/V Alarm r A/V Alarm r A/V Alarm r A/V Alarm <br /> Are flow restrictors installed on vent piping? P Yes r No rV Yes r No P Yes r No r Yes r No <br /> At what level in the tank is the overfill prevention set to 97.75 95 109.25 <br /> activate?(Inches from bottom of tank.) <br /> What is the percent capacity of the tank at which the 90% 90% 89% <br /> overfill prevention equipment activates? <br /> Is the overfill prevention in proper operating condition r Yes r Yes r Yes r Yes <br /> to respond when the substance reaches the r No r No r No r No <br /> appropriate level? in section v (Specify ) (Specify ) (Specify ) <br /> (Specify' ) (Speci in section Vm section Vin section V <br /> N. SUMMARY OF TESTING RESULTS <br /> Overfill Prevention Inspection Results W Pass r Fail r P Pass r Fail r Pass r Fail r Pass r Fail <br /> V. COMMENTS <br /> All items marked failed above must be explained in this section. Any additional comments may also be provided here. <br /> VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS <br /> I hereby certify that the spill containers were tested in accordance with California Code of Regulations,title 23,division 3,chapter 16,section <br /> 2637.1 and all the information contained herein is accurate. <br /> UST Service Technician Signature <br /> If the facility has more components than this form accommodates,additional copies of this page may be attached. <br /> CERS=California Environmental Reporting System,ID=Identification,UST=Underground storage tank,ICC=International Code Council <br />
The URL can be used to link to this page
Your browser does not support the video tag.