SAN J O A R N Environmental Health Department <br /> i , �V <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CAGASOLINE EXPRESS 2115 W YOSEMITE AVE, MANTECA March 25, 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 314 HSC 25290.1,25290.2, 25291 Failed to have secondary containment or secondary containment not tight. <br /> OBSERVATION:About 40-50 ml of brine was found in the 87 and 97 STP sumps, indicating a leak in the secondary <br /> containment. <br /> REGULATION GUIDANCE: Secondary containment shall be impervious to the liquid and vapor of the substance <br /> contained and constructed to prevent structural weakening as a result of contact with any hazardous substances <br /> released from the primary containment. <br /> CORRECTIVE ACTION: Immediately contact a properly licensed,trained, and certified contractor to make repairs <br /> to the UST system under permit and inspection of the EHD. <br /> This is a repeat violation, Class II. <br /> 316 HSC 25290.1(c3), 25290.2(c3)Secondary containment not constructed to prevent water intrusion (after Jul 2003). <br /> OBSERVATION:At the time of the inspection the following amount of liquid was observed: <br /> -Approximately 3 1/2 gallons of liquid was observed in the 87 fill sump. <br /> -Approximately 2 gallons of liquid was observed in the 91 product fill sump <br /> -Approximately 1 cup of liquid was observed in the diesel fill sump. <br /> REGULATION GUIDANCE: Secondary containment shall be constructed to prevent any water intrusion into the <br /> system by precipitation, infiltration, or surface runoff. <br /> CORRECTIVE ACTION: The service technician removed all liquid from the fill sumps and returned the sensor to its <br /> proper location. Immediately contact a properly licensed, trained, and certified contractor to address the water <br /> intrusion into the sumps under permit and inspection of the EHD. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> The monitoring system certification was conducted on 3/25/2020. The testing was not witnessed in its entirety. <br /> Looked inside all sumps and UDCs. Verified proper sensor locations. Verified spill bucket 5 gallon capacity. An <br /> inspection checklist was provided to the facility operator on the day of inspection. A complete report was <br /> finished on 6/30/2020 and replaces the initial checklist. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, within 30 days of receiving the complete inspection report. <br /> To minimize person to person contact EHD is choosing to write the name of person receiving the report instead <br /> of having them sign. Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate <br /> FA0017819 PR0526335 SCO01 03/25/2020 <br /> EHD 23-01 Rev.9/20/2019 Page 8 of 9 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />