My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRINITY
>
10424
>
2200 - Hazardous Waste Program
>
PR0525969
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:02:22 PM
Creation date
7/6/2020 3:26:21 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0525969
PE
2247
FACILITY_ID
FA0015147
FACILITY_NAME
TARGET T1862
STREET_NUMBER
10424
STREET_NAME
TRINITY
STREET_TYPE
PKWY
City
STOCKTON
Zip
95219
APN
066-020-210-000
CURRENT_STATUS
01
SITE_LOCATION
10424 TRINITY PKWY
P_LOCATION
01
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
170
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN10 A Q U I N Environmental Health Department <br /> COUNTY <br /> RCRA LARGE QUANTITY HAZARDOUS WASTE GENERATOR INSPECTION REPORT <br /> Facility /ryy Facility Inspection 024141) <br /> Name: �1fr I I U � v / �Address: Date: 4 <br /> Labeling and Storage V R COS <br /> 601 CCR 66262. 34(a) Stored hazardous waste on site longer than 90 days without a permit or authorization (V380) ❑ ❑ ❑ <br /> 602 66262 .34 e 1 B CCR Stored satellite accumulated waste on site longer than one year or 90 days after fill date (V794) ❑ ❑ ❑ <br /> CCR <br /> 603 66262 , 34(e 1 C Failed to mark initial accumulation start date on satellite containers (V796) ❑ ❑ ❑ <br /> 604 CCR 66262.34(e)(3) Failed to mark satellite containers with date filled within three days (V798) ❑ ❑ ❑ <br /> 605 CCR 66262.34(f) Failed to completely label containers or tanks of hazardous waste (V379) ❑ ❑ <br /> 606 CCR 66266, 81 (a)(3) Failed to meet lead acid battery storage requirements for hazardous waste management exemption (V769) ❑ [1 [a] <br /> 607 CCR 66266, 81 (b) Damaged lead acid batteries not properly managed and labeled (V770) ❑ ❑ ❑ <br /> 608 CCR 66266. 130 Failed to properly manage used oil and fuel filters (V771 ) ❑ ❑ ❑ <br /> 609 HSC 25143.2, Failed to meet requirements for claimed excluded recyclable materials (V772) ❑ ❑ ❑ <br /> 25143 .9 <br /> 610 HSC 25200a3, 1 (b) Failure of laboratory to comply with hazardous waste accumulation area requirements (V922) ❑ ❑ ❑ <br /> Universal Waste V R COS <br /> 701 CCR 66273. 32(a) Failed to notify the EPA RA to obtain an EPA ID# prior to accumulating >5000kg of UW (V773) ❑ ❑ ❑ <br /> 702 CCR 66273.32(c) Electronic device and CRT handler failed to notify DTSC 30 days prior to accepting offsite UW (V774) ❑ ❑ ❑ <br /> 703 CCR 66273.33(a) Failed to store UW batteries in a manner that prevents breakage and release to the environment (V775) ❑ ❑ ❑ <br /> 704 CCR 66273. 33(b) Failed to properly manage universal waste lamps (V776) ❑ ❑ ❑ <br /> 705 CCR 66273. 33(c) Failed to properly manage mercury containing universal waste (V777) ❑ ❑ ❑ <br /> 706 CCR 66273. 33.5 Failed to properly manage universal waste electronic devices , CRTs or CRT glass (V778) ❑ ❑ ❑ <br /> 707 CCR 66273.34 Failed to label universal waste to identify type of universal waste (V781 ) ❑ ❑ ❑ <br /> 708 CCR 66273.35 Stored UW onsite greater than one year or was unable to demonstrate the time UW has been stored <br /> ❑ ❑ ❑ <br /> 782 <br /> 709 CCR 66273. 36 Failed to train employees and maintain records on UW handling and emergency procedures (V783) ❑ ❑ ❑ <br /> 710 CCR 66273 . 39 Failed to keep complete records of each shipment of universal waste for three years (V785) ❑ ❑ ❑ <br /> 711 HSC 25201 . 16(e) Failed to manage aerosol cans in a manner that prevents the unauthorized release of waste (V779) ❑ ❑ ❑ <br /> 712 HSC 25201 . 16(f) Failed to properly manage containers of waste aerosol. cans (V780) ❑ ❑ ❑ <br /> 713 HSC 25201 . 16(g) Failed to store used aerosol cans in an accumulation container (V802) ❑ ❑ ❑ <br /> 714 HSC 25201 . 16(h) (4) No written operating procedure for aerosol can processing (V827) ❑ ❑ ❑ <br /> 715 HSC 25201 . 160) Failed to submit or amend notification for aerosol can processing (V829) ❑ ❑ ❑ <br /> 716 CCR 66273.40(a)(4) UW handler sending devices/CRTs/CRT glass to foreign destination failed to submit notification (V333) ❑ ❑ ❑ <br /> 717 CCR 66273.32(b) Failed to obtain an ID number from DTSC prior to accumulating >5000kg of non-RCRA UW (V315) ❑ ❑ ❑ <br /> 718 CCR 66273.32(d) Failure of a UW handler to submit a complete annual report to DTSC (V331 ) ❑ ❑ ❑ <br /> 719 CCR 66273 .38 Failure of UW handler to transfer UW to the appropriate destination facility (V320) 11 ❑ <br /> Appliance Recyclers V R COS <br /> 801 HSC 25211 .4 Failure to obtain Certified Appliance Recycler certification (CAR) (V886) ❑ ❑ ❑ <br /> 802 HSC 25211 .2, Failure of a CAR to provide documentation that materials that require special handling have been removed ❑ ❑ ❑ <br /> 25211 .3 887 <br /> 803 HSC 25212 Failure of a CAR to properly remove and dispose of all materials that require special handling (V923) ❑ ❑ ❑ <br /> Other Violations V R COS <br /> 3110 See below Unlisted Administration/Documentation violation (V394) r(n] <br /> ❑ ❑ <br /> 3120 See below Unlisted Training violation (V395) 11 113130 See below Unlisted Operations/Maintenance violation (V396) ❑ ❑ <br /> 3140 See below Unlisted Release/Leaks/Spills violation (V397) ❑ ❑ <br /> Received �() Inspector <br /> By (initial): CN) Initial: <br /> EHD 22-03 REV 11 /03/17 Page 3 HW RCRA INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.