SITE INFORMATION AND CORRESPONDENCE
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WOODBRIDGE
>
3750
>
2900 - Site Mitigation Program
>
PR0526222
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/7/2020 9:11:36 AM
Creation date
7/7/2020 9:05:37 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0526222
PE
2965
FACILITY_ID
FA0017743
FACILITY_NAME
LODI VINTNERS INC
STREET_NUMBER
3750
Direction
E
STREET_NAME
WOODBRIDGE
STREET_TYPE
RD
City
ACAMPO
Zip
95220
APN
01322007
CURRENT_STATUS
01
SITE_LOCATION
3750 E WOODBRIDGE RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CALIFORNIA REGIONAL WATER QUALITY CONTROL BOARD <br /> CENTRAL VALLEY REGION <br /> REVISED MONITORING AND REPORTING PROGRAM NO. 93-112 <br /> FOR <br /> LODI VINTNERS, INC. D <br /> SAN JOAQUIN COUNTY <br /> This Revised Monitoring and Reporting Program (MRP) incorporates requirements for monitoring <br /> process wastewater, wastewater ponds, solid waste, and groundwater. This MRP is issued pursuant to <br /> Water Code Section 13267. The Discharger shall not implement any changes to this MRP unless and <br /> until a revised MRP is issued by the Executive Officer. <br /> All samples should be representative of the volume and nature of the discharge. The time, date, and <br /> location of each sample shall be recorded on the sample chain of custody form. Process wastewater flow <br /> monitoring shall be conducted continuously using a flow meter and shall be reported in cumulative <br /> gallons per day. <br /> Field test instruments (such as pH and dissolved oxygen meters) may be used provided that: <br /> 1. The operator is trained in the proper use of the instrument; <br /> 2. The instruments are field calibrated prior to each use; <br /> 3. Instruments are serviced and/or calibrated by the manufacturer at the recommended frequency; and <br /> 4. Field calibration reports are submitted as described in the "Reporting" section of this MRP. <br /> INFLUENT MONITORING <br /> The process wastewater flow rate shall be metered prior to entering the wastewater ponds. Influent <br /> monitoring for the process wastewater system shall include at least the following: <br /> Constituents Units Type of Sample Sampling Frequency Reporting Frequency <br /> Flow gallons Continuous Dailyl Monthly <br /> Continuous monitoring requires daily meter reading or automated data collection. <br /> POND MONITORING <br /> Samples shall be collected from established sampling stations located in areas that will provide <br /> representative samples of the water in each wastewater pond. Samples shall be collected for each of the <br /> parameters listed below. Freeboard shall be measured vertically from the surface of the pond water to the <br /> lowest elevation of the surrounding berm and shall be measured to the nearest 0.1 feet. Monitoring of the <br /> ponds shall include, at a minimum, the following: <br /> Constituent Units Type of Sampling Reporting <br /> Sample Frequency Frequency <br /> Dissolved Oxygen 1,2 mg/L Grab Weekly Monthly <br /> Freeboard2 feet(±0.1) Measurement Weekly Monthly <br />
The URL can be used to link to this page
Your browser does not support the video tag.