I <br /> 18 December 2401 <br />' AGE-NC Project No 01-0839 <br /> Page 8 of 8 <br />' 4 6 BORING ABANDONMENT <br /> The soil boring not completed as a monitoring well will be permanently sealed to prevent potential <br />' vertical migration of potential contaminants Soil borings shall be abandoned by backfilling with <br /> bentonite or cement-bentonite slurry from the total depth to surface grade The PHS-EHD will be <br /> notified for grout inspection at least 48 hours prior to conducting grouting procedures <br /> I <br /> I <br /> I <br /> I <br /> I <br /> Advanced GeoEnvironmentat,Inc <br />