Laserfiche WebLink
Appendix VI <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://www.swrcb.ca.gov.) <br /> MONI TORI NG SYSTEM CERTI FI CATI ON <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each monitoring <br /> system control panel by the technician who performs the work.A copy of this form must be provided to the tank system owner/operator.The <br /> owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: Fed Ex Ground Bldg. No.: <br /> Site Address: 120 S Hansen Road City: Tracy Zip: 95304 <br /> Facility Contact Person: Jessie Andrada Contact Phone No.: 916-826-3081 <br /> Make/Model of Monitoring System: Veeder Root TLS-350 Date of Testing/Servicing: 7/17/2018 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment ins ected/serviced: <br /> Tank I D: T-1-Diesel Tank I D: T-3-Biodiesel <br /> In-Tank Gauging Probe. Model: mag F7 In-Tank Gauging Probe. Model: mag <br /> F Annular Space or Vault Sensor. Model: 794380-303 Annular Space or Vault Sensor. Model: 794380-303 <br /> Piping Sump/Trench Sensor(s). Model: 794380-208/303 Piping Sump/Trench Sensor(s). Model: 794380-208/303 <br /> Fill Sump Sensor(s). Model: 794380-208/303 Fill Sump Sensor(s). Model: 794380-208/303 <br /> F Mechanical Line Leak Detector. Model: F Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Veeder Root PLLD- F Electronic Line Leak Detector. Model: <br /> I7 Tank Overfill/High-Level Sensor.Model: flapper F Tank Overfill/High-Level Sensor.Model: flapper <br /> Other(specify equipment t e and model in Section E on Page 2). r Other(specify equipment t e and model in Section E on Page 2). <br /> Tank I D: T-2-Diesel Tank I D: <br /> In-Tank Gauging Probe. Model: mag r In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: 794380-303 r Annular Space or Vault Sensor. Model: <br /> F Piping Sump/Trench Sensor(s). Model: 794380-208/303 F Piping Sump/Trench Sensor(s). Model: <br /> F Fill Sump Sensor(s). Model: 794380-208/303 F Fill Sump Sensor(s). Model: <br /> F Mechanical Line Leak Detector. Model: F Mechanical Line Leak Detector. Model: <br /> F Electronic Line Leak Detector. Model: F Electronic Line Leak Detector. Model: <br /> Iy-1 Tank Overfill/High-Level Sensor.Model: flapper F Tank Overfill/High-Level Sensor.Model: <br /> F Other(specify equipment t e and model in Section E on Page 2). F Other(specify equipment t e and model in Section E on Page 2). <br /> Dispenser 1 Dispenser 1 SAT/2 <br /> I D: I D: <br /> Dispenser Containment Sensor(s).Model: 794380-208\303 I7 Dispenser Containment Sensor(s).Model: 794380-208/303 <br /> F7 Shear Valve(s). I%0_ Shear Valve(s). <br /> r— Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> Dispenser 5/6 Dispenser 2 SAT/3 <br /> I D: I D: <br /> F7 Dispenser Containment Sensor(s).Model: 794380-208/303 F7 Dispenser Containment Sensor(s).Model: 794380-208/303 <br /> F7 Shear Valve(s). I%0_ Shear Valve(s). <br /> I— Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> Dispenser 7/8 Dispenser 3 SAT/4 <br /> I D: I D: <br /> F7 Dispenser Containment Sensor(s).Model: 794380-208/303 I7 Dispenser Containment Sensor(s).Model: 794380-208/303 <br /> F7 Shear Valve(s). I%0_ Shear Valve(s). <br /> F_ Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines.Attached to <br /> this Certification is information(e.g. manufacturers'checklists)necessary to verify that this information is correct and a Plot Plan showing the layout of <br /> monitoring equipment. For any equipment capable of generating such reports,I have also attached a copy of the report; (check all that apply): F System set- <br /> up F Alarm history report <br /> Technician Name(print): Brent Bowen Signature: <br /> Certification No.: B42815 License. No.: 743160 Class'A' <br /> Testing Company Name: Tanknology Phone No.: (800)800-4633 <br /> Testing Company Address: 11000 N. MoPac Expressway Suite 500 Date of Testing/Servicing: 7/17/2018 <br /> Monitoring System Certification Page 1 of 4 12/07 <br />