Laserfiche WebLink
' FRIEDMAN & BRUYA, INC <br /> ENVIRONMENTAL CHEMISTS <br /> Date of Report October 25, 1995 <br />' Date Received October 18, 1995 <br /> Protect: U-Haul, P0 #709-50 <br /> QUALITY ASSURANCE RESULTS <br /> FOR THE ANALYSIS OF THE SOIL SAMPLE FOR <br />' BENZENE, TOLUENE, ETHYLBENZENE, <br /> XYLENES AND GASOLINE <br /> USING EPA METHODS 8020 AND 8015 <br />' Laboratory Code 62855 (Duplicate) <br /> Relative <br /> Reporting Sample Duplicate Percent Acceptance <br /> Analyte, Units Result Result Difference Criteria <br /> Gasoline ug/g (ppm) <1 <1 vm 0-20 <br /> Laboratory Code 62855 (Matrix Spike) <br />' Relative <br /> Reporting Spike Sample % Recovery Acceptance Percent <br /> Analyte, Units Level Result MS MSD Criteria Difference <br /> Gasoline ug/g (ppm) 10 <1 76 77 68-112 1 <br /> Laboratory Code Spike Blank <br />' Relative <br /> Reportmg Spike % Recovery Acceptance Percent <br /> Analyte, Units Level MS MSD Criteria Difference <br />' Benzene ug/g (ppm) 1 86 76-109 <br /> Toluene ug/g (ppm) 1 87 74-110 <br /> Ethylbenzene ug/g (ppm) 1 89 74-110 ! <br />' Xylenes ug/g (ppm) 3 91 64-118 <br /> Gasoline ug/g (ppm) 10 88 90 61-130 2 <br /> 1 <br />' n1" No analyte was detected RPD results are not meaningful <br />