Laserfiche WebLink
® CGRS UST Spill Bucket <br /> SOLUTIONS DELIVERED <br /> Integrity Testing Form <br /> Underground Storage Tanks (UST) Program <br /> Instructions on Page 3 <br /> Purpose: This procedure is to test the leak integrity of single-and double-walled spill buckets.See reverse side for <br /> basic hydrostatic testing instructions.Consult PEI/RP1200,Section 6.2 for hydrostatic test method,Section 6.3 for <br /> single-walled vacuum test method,and Section 6.4 for double-walled vacuum test method. <br /> Testing Information <br /> 1. Tank number T6:UNL T7:UNL <br /> 2. Product stored Unleaded Unleaded <br /> 3. Spill bucket capacity 5 gallons 5 gallons <br /> 4. Manufacturer OPW OPW <br /> 9 Single-walled 9 Single-walled ❑Single-walled ❑Single-walled ❑Single-walled ❑Single-walled <br /> 5. Construction ❑Double-walled ❑Double-walled ❑Double-walled ❑Double-walled ❑Double-walled ❑Double-walled <br /> *Hydrostatic @1 Hydrostatic ❑Hydrostatic ❑Hydrostatic ❑Hydrostatic ❑Hydrostatic <br /> ❑Vacuum ❑Vacuum ❑Vacuum ❑Vacuum ❑Vacuum ❑Vacuum <br /> ❑Single-walled ❑Single-walled ❑Single-walled ❑Single-walled ❑Single-walled ❑Single-walled <br /> 6. Testtype ❑Double-walled ❑Double-walled ❑Double-walled ❑Double-walled ❑Double-walled ❑Double-walled <br /> 9 Product ❑Product ❑Product ❑Product ❑Product ❑Product <br /> 7. Spill bucket type ❑Vapor ❑Vapor ❑vapor ❑Vapor ❑Va or ❑Vapor <br /> 8. Liquid and debris <br /> removed from spill <br /> bucket:" [5 Yes ❑No I]Yes ❑No ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No <br /> 9. Visual inspection <br /> (No cracks,loose parts or <br /> separation of the bucket <br /> from the fill pipe.)? 19 Pass ❑Fail ©Pass ❑Fail ❑Pass ❑Fail ❑Pass ❑Fail ❑Pass ❑Fail ❑Pass ❑Fail <br /> 10. Tank riser cap included in <br /> test? 0 Yes ❑No❑NA [!)Yes ❑No❑NA ❑Yes ❑No❑NA ❑Yes ❑No❑NA ❑Yes ❑No❑NA ❑Yes ❑No❑NA <br /> 11. Is drain valve included in <br /> test? B Yes ❑No❑NA [9 Yes ❑No❑NA ❑Yes ❑No❑NA ❑Yes ❑No❑NA ❑Yes ❑No❑NA ❑Yes ❑No❑NA <br /> 12. Starting level 11.25' 11.50" <br /> 13. Test start time 8:20 am 8:20 am <br /> 14. Ending level 11.25' 11.50" <br /> 15. Test end time 9:20 am 9:20 am <br /> 16. Test period 1 hour i hour <br /> 17. Level chan e 0 0 <br /> Test results: p. Pass ❑Fail 9 Pass ❑Fail ❑Pass ❑Fail ❑Pass ❑Fail ❑Pass ❑Fail ❑Pass ❑Fail <br /> Pass/fail criteria:Must pass visual inspection.Hydrostatic:Water level drop of less than 1/8 inch;Vacuum single-walled only; <br /> Maintain at least 26 inches water column;Vacuum double-walled,maintain at least 12 inches water column. <br /> Comments: <br /> *All liquids and debris must be disposed of properly. <br /> Testing company �'. CGRS <br /> name: Tester's name: Garrett Warren <br /> Date . 01/14/2020 Tester's signature: <br /> GPH=Gallons per hour,Y=Yes,N=No,NA=Not applicable,VPH=Vacuum/PressurefHydrostatic,ID=Identification <br />