My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0011541
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
2701
>
3500 - Local Oversight Program
>
PR0540315
>
ARCHIVED REPORTS_XR0011541
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/7/2020 3:20:23 PM
Creation date
7/7/2020 2:48:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0011541
RECORD_ID
PR0540315
PE
3526
FACILITY_ID
FA0023046
FACILITY_NAME
U-HAUL FACILITY NO 710050
STREET_NUMBER
2701
Direction
N
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95215
APN
11708014
CURRENT_STATUS
01
SITE_LOCATION
2701 N WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
436
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ParaQiaph e Emplovee Training All Blaes Enviioaunental field personnel are 40-hour trained and S-hour <br /> updated ti'o specialized (ceitified) trauiin, re uired <br /> Paragraph f Medial Surveillance All Blaes Envi miunental field personnel are current with their medical <br /> certifications and record keeping requirements <br /> Paragraph g Personal Protective Field work iequnes Level D personal protection equipment This includes <br /> Equipment normal clothes, hardhat, steel-toe boots, safety glasses, and ear plugs <br /> Personnel working with the drill rig will also wear leather gloves <br /> Paragraph g Safe Work Practices Safe work piactices are provided as Attachment 5 <br /> Paragraph h Air Monitoring A photoionization detector (PID) will be used to measure volatile organic <br /> compounds in the wort. area If readings exceed 5 parts per million in the <br /> woi k zone (the area within approximately 10-radial feet of the drill rig or in <br /> the i eniedial system enclosure for greater than 20 seconds at a time,PPE will <br /> be upgraded to modified Level C(Level D plus%-face respirator with organic <br /> cartrid es and HEPA filters) <br /> Paiagraph i Confined Space Entry Confined space entry is not required Compliance with 29CFR 1910 146 is <br /> not applicable <br /> Paiagiaph j Spill Containment/ All soil cuttings produced during well installation activities will be <br /> Waste Disposal temporarily containerized in 55-gallon DOT approved drums Following <br /> completion of soil sampling and profiling,the soil and decon water drums will <br /> be transported off-site by a state certified transporter for proper recycling <br /> and/or disposal <br /> Paragraph k Decontamination Liquid Alconox and water will be available for decontamination and site <br /> clean-Up Additional PPE will be wiped down as necessary <br /> Paragraph 1 Emergency Response Emei gency siWations will iecluite calling 911 for emergency assistance This <br /> includes fire, police and emergency medical <br /> In case of an emergency on site,all persoruiel will evacuate the work area and <br /> congregate at the southeastern property boundary, near the intersection of <br /> Sanquinetti Lane and North Wilson Way <br /> For situations not requiring serious medical assistance,injured persons can be <br /> driven to Saint Joseph Medical Center A map to the hospital is included as <br /> Attachment 4 <br /> Contact numbers for emergencies not requiring 911 are as follows <br /> Saint Joseph Medical Center 209-943-2000 <br /> 1800 N California St, Stockton,CA, approx 1 29 miles from site <br /> Stockton Police Department 209-937-8377 <br /> 22 E Market St, Stockton, CA, approx 2 41 miles from site <br /> Stockton Fire De artment 209-937-8801 <br /> 425 E El Dorado St, Stockton, CA,approx 2 08 miles from site <br /> Paragraph's Additional Items On this project, compliance with these items is not required <br /> m, n, o, and <br />
The URL can be used to link to this page
Your browser does not support the video tag.