Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> SECONDARY CONTAINMENT TESTING REPORT FORM (Page -I of 6) <br /> Type of Action ❑ Installation Test ❑ Repair Test ❑ Six Month Test ❑x 36 Month Test <br /> I . FACILITY INFORMATION <br /> CERS ID Date of Secondary Containment Test <br /> 10182105 3/ 16/2020 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) <br /> San Joaquin County Jail - Op #2 <br /> Business Site Address City ZIP Code <br /> 7000 Michael Canliss Boulevard French Camp 95231 <br /> II . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Test (Print as shown on the ICC Certification) Phone # <br /> Benjamin Duncan ( 707 ) 621 -0378 <br /> Contractor / Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> Tank Tester License #90- 1120 524680MT 3/21 /2021 <br /> III . SUMMARY OF SECONDARY CONTAINMENT TESTING RESULTS <br /> TANK ID : (By tank number, stored product, etc.) A T- 1 -Dyed Diesel B T-2-Dyed Diesel C D <br /> Tank Containment <br /> Tightness Test Result Z Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Product Piping Containment <br /> Tightness Test Result E Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Communication Test Result ❑ Pass ❑ Fail O NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Remote Fill Piping Containment <br /> Tightness Test Result ❑ Pass ❑ Fail O NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Communication Test Result ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Vent Piping Containment <br /> Tightness Test Result ❑ Pass ❑ Fail Z NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Communication Test Result ❑ Pass ❑ Fail Z NA ❑ Pass [] Fail ENA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Vapor Recovery Piping Containment <br /> Tightness Test Result ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail Z NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Communication Test Result ❑ Pass ❑ Fail Z NA ❑ Pass ❑ Fail Z NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Turbine / Product Piping Sump <br /> Tightness Test Result E Pass ❑ Fail ❑ NA E Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Fill Riser Sump <br /> Tightness Test Result ❑ Pass ❑ Fail Z NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> VENT / TRANSITION SUMP ID : a b C d <br /> Tightness Test Result ❑ Pass ❑ Fail Z NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> UDC ID : 1 2 3 4 <br /> Tightness Test Result ❑ Pass ❑ Fail Z NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail Z NA ❑ Pass ❑ Fail Z NA <br /> UDC ID : 5 6 7 8 <br /> Tightness Test Result ❑ Pass ❑ Fail Z NA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail Z NA ❑ Pass ❑ Fail E NA <br /> UDC ID : 9 E[:IPass <br /> 11 12 <br /> Tightness Test Result ❑ Pass ❑ Fail ENA ❑ Fail ENA ❑ Pass ❑ Fail E NA ❑ Pass ❑ Fail E NA <br /> All items marked "Fail' or "NA " must be explained in their respective "COMMENTS " section. <br /> IV. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTINGN, - ISTESTI:NG > � %, <br /> 1 hereby certify that the secondary containment was tested in accordance with California C4&afRegulations' , Tale 23 , P"IVIsion <br /> 3 , Chapter 16, Section 2637 and all the information contained herein is accurate. <br /> UST Service Technician Signature (�f <br /> �.�%LIBll�fl2�il?r ��!•192C1.1i1?r <br /> CERS = California Environmental Reporting System, ID = Identification, UST = Underground Storage Tank, ICC = International Code Council, NA = Not Applicable UDC = Under- <br /> Dispenser Containment <br />