Laserfiche WebLink
40 CFR 268.48 TABLE UTS—UNIVERSAL TREATMENT STANDARDS (Continued) <br /> `CAS means Chemical Abstract Services.When the waste code and/or regulated constituents are described as a combination of a chemical with its <br /> salts and/or esters,the CAS number is given for the parent compound only. <br /> Concentration standards for wastewaters are expressed in mg/I are based on analysis of composite samples. <br /> 'Except for Cyanides(Total and Amenable)the non-wastewater treatment standards expressed as a concentration were established, in part,based <br /> upon incineration in units operated in accordance with the technical requirements of 40 CFR part 264,subpart 0 or 40 CFR part 265,subpart 0,or <br /> based upon combustion in fuel substitution units operating in accordance with applicable technical requirements.A facility may comply with these <br /> treatments standards according to provisions in 40 CFR 268.40(4).All concentration standards for nonwastewaters are based on analysis of grab <br /> samples. <br /> ^Both Cyanides(Total)and Cyanides(Amenable)for non-wastewaters are to be analyzed using Method 9010 or 9012,found in"Test Methods for <br /> Evaluating Solid Waste, Physical/Chemical Methods', EPA Publication SW-846,as incorporated by reference in 40 CFR 260.11,with a sample size of <br /> 10 grams and a distillation time of one hour and 15 minutes. <br /> 5These constituents are not"underlying hazardous constituents'in characteristic wastes,according to the definition at§268.2(i). <br /> °Between August 26, 1996, and August 26, 1997,these constituents are not"underlying hazardous constituents"as defined at§268.2(i)of this Part. <br /> Note:NA means not applicable. <br /> Please complete as applicable: <br /> Wastes with organic constituents having treatment standards expressed as concentration levels based in whole or in part <br /> on the analytical detection limit alternative specified in§268.40(d). <br /> El11 gr,=y under penalty of law that I have personally examined and am familiar with the treatment technology and operation of the treatment <br /> r ri-nicess used 10 5ufir.'art this certification.Based on my inquiry of those individuals immediately responsible for obtaining this information, <br /> 1 believe that the non-wastewater organic constituents have been treated by combustion units as specified in 268 42.Table 1.I have been <br /> unable to detect the non-wastewater organic constituents,despite having used best good-faith efforts to analyze for such constituents.i am <br /> aware there are significant penalties for submitting a false certification,including the possibility of fine and imprisonment. <br /> Wastes with treatment standards expressed as concentrations in the waste extract Toxicity Characteristic Leaching <br /> Procedure(TCLP). <br /> ❑I certify under penalty of law that I have personally examined and am familiar with the treatment technology and operation of the treatment <br /> process used to support this certification.Based on my inquiry of those individuals immediately responsible for obtaining this information, <br /> I believe that the treatment process has been operated and maintained properly so as to comply with the treatment standards specified <br /> in 40 CFR 268.40 without impermissible dilution of the prohibited waste.I am aware there are significant penalties for submitting a false <br /> certification,including the possibility of fine and imprisonment. <br /> Alternative Treatment Standard Lab Pack <br /> Manifest Line No. C I I I <br /> EJ I certify under penalty of law that I personally have examined and am familiar with the waste and that the lab pack contains only wastes that <br /> have not been excluded under Appendix IV to 40 CFR Part 268 and that this lab pack will be sent to a combustion facility in compliance with <br /> the alternative treatment standards for lab packs at 40 CFR 268.42(c).I am aware that there are significant penalties for submitting a false <br /> certification,including the possibility of fine or imprisonment. <br /> A I hereby certify under penalty of law that there are no PCBs(polychlorinated biphenyls)contained in the oil waste being manifested to <br /> Pacific Resource Recovery.I also understand that a sample of the load will be retained and that the generator will be responsible for the <br /> clean-up of contaminated equipment,tanks,etc.if PCBs are present in the waste. <br /> Benzene NESHAP Control Requirement: <br /> For Chemical Manufacturers, Petroleum Refineries, Coke By-Product Facilities and RCRA TSDFs handling wastes subject to 40 CFR 61 subpart FF <br /> ONLY: <br /> This waste is a"Controlled Benzene Waste"which is subject to the notification <br /> requirements of 40 CFR 61 Subpart FF. <br /> Manifest Line No. <br /> California List Wastes: <br /> 11 Liquid hazardous wastes having a pH less than or equal to 2.0 <br /> ElLiquid hazardous wastes containing PCBs at a concentration greater than or equal to 50 ppm <br /> nLiquid hazardous wastes that contain HOCs in total concentration greater than or equal to 1000 mgA <br /> ElNonliquid hazardous wastes containing HOCs in total concentration greater than or equal to 1000 mg/kg <br /> DFree(amenable to chlorination)cyanides greater than or equal to 1000 mgA <br /> One or more of the following metals greater than or equal to the following: <br /> Arsenic and/or compounds:500 mgA <br /> Cadmium and/or compounds:100 mgA <br /> Chromium and/or compounds:500 mgA <br /> Lead and/or compounds:500 mg/1 <br /> Mercury and/or compounds:20 mgA <br /> Nickel and/or compounds 134 mg/I <br /> Selenium and/or compounds:100 mgA <br /> Thallium and/or compounds-130 mg/l <br /> apvo, o�,i-,z,a <br /> Page 3of? <br />