Laserfiche WebLink
copy of the Contingency Plan and any additional documentation will be <br /> attached to this Plan . <br /> vi) I certify that I have satisfied the requirement to prepare and implement a Plan under <br /> § 112 . 3 and all of the requirements under § 112 . 6 (a) . I certify that the information <br /> contained in this Plan is true . <br /> ( 1 ) Signature : 6 /. / SGL— Title : Safety Director <br /> (2) Print Name : William Buckman Date : 0 fla <br /> Record of Plan Review and Amendments <br /> Five Year Review (§ 112 . 5 (b)) . <br /> 1 ) Complete a review and evaluation of this SPCC Plan at least once every five years . As a <br /> result of the review, amend this Plan within six months to include more effective prevention <br /> and control measures for the facility, if applicable . Implement any SPCC Plan amendment as <br /> soon as possible, but no later than six months following Plan amendment . Document <br /> completion of the review and evaluation, and complete the Five Year Review Log in the <br /> attachments . If the facility no longer meets Tier I qualified facility eligibility, the <br /> owner/operator must revise the Plan to meet Tier II qualified facility requirements , or <br /> complete a full PE certified Plan . <br /> Table G4 Technical Amendments (§ 112 . 5(a) , c) and 112. 6(a) (2) <br /> This SPCC Plan will be amended when there is a change in the facility design, XD <br /> construction, operation, or maintenance that materially affects the potential for a <br /> discharge to navigable waters or adjoining shorelines . Examples include adding <br /> or removing containers , reconstruction, replacement, or installation of piping <br /> systems , changes to secondary containment systems , changes in product stored at <br /> this facility, or revisions to standard operating procedures . <br /> Any technical amendments to this Plan will be re- certified in accordance with FX] <br /> Section I of this Plan. ( § 112 . 6 (a) (2)) <br /> Plan Requirements <br /> Oil Storage Containers (§ 112 . 7(a) (3) (1)) : <br /> Table G2 Oil Storage Containers and Capacities <br /> This table includes a completed list of all oil storage containers XD <br /> (aboveground containers and completely buried tanks) with capacity of 55 <br /> US gallons or more , unless otherwise exempt from the rule . For <br /> mobile/portable containers, an estimated number of containers , types of oil, <br /> and anticipated capacities are provided . <br /> BULK STORAGE CONTAINERS <br /> Oil Storage Container (indicate Type of Oil Shell <br /> whether above ground (A) or Capacity <br /> completely buried (B)) (gallons) <br /> Chrisp Company <br /> Prepared By William Buckman, Safety Director Page 8 of 31 <br />