Laserfiche WebLink
AI <br /> MONITORING WELL <br /> CONSTRUCTION DETAILS <br /> PROJECT NO 19011.05 MONITORING WELL NO.. Mw-3 <br /> LOCATEON: Beacon #419 <br /> 2350 Waterloo Road ELEVATION, 21 38 feet <br /> Stockton, California <br /> Protective Casing <br /> A <br /> Locking Water Tight Cap <br /> Flush Gm" Wed Conetiwdon <br /> Diameter and Mat'[ 12—inch steel <br /> Total length 12 ides <br /> Length Above Ground 1/4 inch <br /> Thickness and Type of Seal 2 feet, concrete <br /> Diameter, Matl and 4 inch, SCH 40 PVC, <br /> joint Type of Fuer Prpe flush thread <br /> N <br /> -' Type of Backfill <br /> Around Riser cament/ 5X <br /> bentonFte grout <br /> Thickness and Type 2 feet <br /> 1 of Seal bentonrte chips <br /> Distance of Filter Sand 2 feet <br /> Above Top of Screen <br /> Type of Filter J3 lonestar <br /> Around Screen <br /> Monitoring Well Mat'1 SCH 40 PVC <br /> Screen Gauge/Slot Size 0 020 inch <br /> Diameter and Length 4 inch, 20 feet <br /> of Screen <br /> Depth to Bottom 85 feet <br /> of Monitoring Well <br /> Depth to the Bottom 85 feet <br /> of Filter Sand <br /> 10 in <br /> MONITORING WELL WATER LEVEL MEASUREMENTS <br /> L1 = 0 5 feet Date rime Water Level* <br /> L2 = 64 5 feet <br /> L3 = 20 00 feet 7/8/94 1530 70 28 ft <br /> L4 = 85 00 feet <br /> Completion Date and Time 7/8/94 15 45 * Measuring Point Top Of Casing <br /> ACTON • MICKELSON • VAN DAM, INC. <br /> 4511 Golden Foothill Parkway, #1 <br /> El Dorado Hills, CA 95762 <br />