My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
7611
>
2300 - Underground Storage Tank Program
>
PR0231511
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/30/2021 10:27:32 AM
Creation date
7/9/2020 11:37:20 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231511
PE
2361
FACILITY_ID
FA0003695
FACILITY_NAME
ESTES TRUCKING
STREET_NUMBER
7611
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
17705029
CURRENT_STATUS
01
SITE_LOCATION
7611 S AIRPORT WAY
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health DepartmentUnderground Storage Tank Program Inspection ReportDate:May 28, 2020Facility Address:7611 S AIRPORT WAY, STOCKTONFacility Name:ESTES TRUCKINGOther Violations2010□ V □ R □ COSUnlisted General violation See belowSUMMARY OF VIOLATIONS(CLASS I, CLASS II, or MINOR - Notice to Comply)RemarksItem #103HSC 25292.2, 25299.30 Failure to submit and maintain complete and current financial responsibility documents. OBSERVATION: Section B of the Certificate of Financial responsibility document was left blank. REGULATION GUIDANCE: Current financial responsibility documents are required to be submitted annually. CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/, and upload the required documents.This is a minor violation.201CCR 2712(b)(1-2) Failure to maintain monitoring, maintenance, and follow up action records. OBSERVATION: Maintenance and monitoring records for the last three years were not found on site. - The 4/4/2019 overfill prevention test results were not found on site. REGULATION GUIDANCE: These records shall be maintained on site for at least three years. Monitoring records include: (1) date and time of all monitoring or sampling; (2) monitoring equipment calibration and maintenance records; (3) results of any visual observations; (4) results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other monitoring equipment, ground water elevations, or other test results; (6) results of inventory readings and reconciliations. CORRECTIVE ACTION: Immediately locate and maintain all missing maintenance and monitoring records for the last three years on site and submit copies to the EHD.This is a minor violation.209CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days. OBSERVATION: The designated operator inspections for the following months were performed more than 30 days after the previous inspection:- Initial inspection on 3/5/2020, next inspection performed on 4/8/2020 ( Five days between the two dates)REGULATION GUIDANCE: The designated operator visual inspections shall be conducted within 30 days or less of the previous inspection. CORRECTIVE ACTION: Ensure that all designated operator inspections are performed within the required time frames.This is a minor violation.FA0003695 PR0231511 SC001 05/28/2020EHD 23-01 Rev. 9/20/2019Underground Storage Tank Program OIRPage 4 of 51868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjcehd.com
The URL can be used to link to this page
Your browser does not support the video tag.