Laserfiche WebLink
January 11, 2019 Lab ID : STK1854539 <br /> Pacific Northwest Oil Customer : 3-16002 <br /> Quality Control-Inorganic <br /> Constituent Method Date/1D Type Units Conc. QC Data DQO Note <br /> Metals <br /> Selenium 3050 (SP 1813098-001) MSD mg/kg 40.00 164% 75-125 435 <br /> MSRPD mg/kg 40.00 6.1% <20 <br /> PDS mg/kg 40.00 140% 75-125 430 <br /> Silver 3050 10/16/18:212330EMM Blank mg/kg ND <0.5 <br /> LCS mg/kg 40.00 103% 85-115 <br /> MS mg/kg 40.00 101% 75-125 <br /> (SP 1813098-001) MSD mg/kg 40.00 120% 75-125 <br /> MSRPD mg/kg 40.00 16.5% <20 <br /> PDS mg/kg 40.00 120% 75-125 <br /> Thallium 3050 10/16/18:212330EMM Blank mg/kg ND <0.5 <br /> LCS mg/kg 40.00 95.8% 85-115 <br /> MS mg/kg 40.00 95.7% 75-125 <br /> (SP 1813098-001) MSD mg/kg 40.00 110% 75-125 <br /> MSRPD mg/kg 40.00 14.0% <20 <br /> PDS mg/kg 40.00 112% 1 75-125 <br /> Vanadium 3050 10/16/18:212330EMM Blank mg/kg ND <0.5 <br /> LCS mg/kg 40.00 98.4% 85-115 <br /> MS mg/kg 40.00 103% 75-125 <br /> (SP 1813098-001) MSD mg/kg 40.00 126% 75-125 435 <br /> MSRPD mg/kg 40.00 18.4% <_20 <br /> PDS mg/kg 40.00 123% 75-125 <br /> inc 3050 10/16/18:212330EMM Blank mg/kg ND <1 <br /> LCS mg/kg 40.00 95.8% 85-115 <br /> MS mg/kg 40.00 277% <%4 <br /> (SP 1813098-001) MSD mg/kg 40.00 500% <%4 <br /> MSRPD mg/kg 40.00 16.4% <_20 <br /> PDS mg/kg 40.00 223% 75-125 1 430 <br /> Mercury 7471 10/10/18:212103AC Blank mg/kg ND <0.03 <br /> LCS mg/kg 0.2500 99.0% 85-115 <br /> MS mg/kg 0.2500 79.0% 75-125 <br /> (CC 1883015-001) MSD mg/kg 0.2500 79.6% 75-125 <br /> MSRPD mg/kg 0.2500 0.6% <20 <br /> Chromium RCRA 11/17/18:213694AC ExBlk mg/L -0.0006 0.01 <br /> PDS m /L 8.000 115% 1 N/A <br /> Copper RCRA 11/17/18:213694AC ExBlk mg/L -0.0013 0.01 <br /> PDS m /L 8.000 129% N/A <br /> Lead RCRA 11/17/18:213694AC ExBlk mg/L 0.0073 0.01 <br /> PDS m /L 8.000 116% 75-125 <br /> ickel RCRA 11/17/18:213694AC ExBlk mg/L 0.0010 0.01 <br /> PDS m /L 1 8.000 112% N/A <br /> Definition <br /> PDS PDS failed,matrix-Post Digestion Spike(PDS)not within Acceptance Range(AR)because of matrix interferences affecting this <br /> analyte.Data was accepted based on the LCS recovery. <br /> CCV :Continuing Calibration Verification-Analyzed to verify the instrument calibration is within criteria. <br /> CCB :Continuing Calibration Blank-Analyzed to verify the instrument baseline is within criteria. <br /> Blank :Method Blank-Prepared to verify that the preparation process is not contributing contamination to the samples. <br /> ExBlk :TCLP/STLC Extraction Blank-Prepared to verify that the preparation process is not contributing contamination to the samples. <br /> LCS :Laboratory Control Standard/Sample-Prepared to verify that the preparation process is not affecting analyte recovery. <br /> MS Matrix Spikes-A random sample is spiked with a known amount of analyte.The recoveries are an indication of how that sample <br /> matrix affects analyte recovery. <br /> MSD :Matrix Spike Duplicate of MS/MSD pair-A random sample duplicate is spiked with a known amount of analyted.The recoveries <br /> are an indication of how that sample matrix affects analyte recovery. <br /> MSRPD :MS/MSD Relative Percent Difference(RPD)-The MS relative percent difference is an indication of precision for the preparation <br /> and analysis. <br /> Amended Page 7 of 8 <br />