Laserfiche WebLink
SA NUJ OAHU I N Environmental Health Department <br /> ■ COUNT Y-- <br /> c/ `p' Greorness grows her,. Time In: 9.30 am <br /> Time Out: 10:00 am <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: NORTH LAKE HOMEOWNERS ASSN Date: 07/08/2020 <br /> Address: 3708 FORT DONELSON DR, STOCKTON 95219 <br /> Owner/Operator: NORTH LAKE HOA Telephone: (209)507-7850 <br /> Program Element: 3611 -PUBLIC POOL/SPA-PRIMARY <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #5 Restrooms and Showers <br /> OBSERVATIONS:Unable to inspect rest rooms.When pool re-opens provide hot/cold water,toilet paper, hand soap, paper <br /> towels, and proper ventilation. <br /> Shower lacks shower head and handles. Provide when pool re-opens. <br /> NOTE: pool currently closed due to concern from COVID-19 <br /> CALCODE DESCRIPTION:Pool operator shall ensure the following facilities are maintained and kept clean:showers, toilets, dressing <br /> facilities, drinking fountains,diaper-changing stations, floors, walls,partitions, doors,and lockers. Showers(except outside)shall be <br /> provided with soap in dispensers. Toilet facilities shall be provided with toilet tissue,hand soap, and paper towels or hot air blowers in <br /> permanently installed dispensers.Pool operator shall provide a minimum of one waste receptacle in each toilet facility. Wooden slats, <br /> duckboards and footbaths are prohibited. (CCR 65535, 65551)Showers and lavatories shall be provided with hot and cold water faucets. <br /> Maximum water temperature at showers and lavatories shall not exceed I I0`F. (CBC 31166) <br /> #7 Pool Deck <br /> OBSERVATIONS:One section of deck lacks small strip of wood between concrete slabs. Install before pool re-opens. <br /> CALCODE DESCRIPTION:An unobstructed 4-foot wide deck of concrete or like material shall be provided and maintained flush with the <br /> top of the pool coping. Deck shall extend completely around the pool and shall further extend 4 feet on both sides and to the rear of any <br /> diving board,ADA device, or slide. (CBC 31146)Pool operator shall keep the pool deck well maintained. (CCR 65535) <br /> #22 Skimmer Assembly <br /> OBSERVATIONS:Float assembly lacked float control valve flap. Provide(corrected at time of inspection by pool service) <br /> CALCODE DESCRIPTION:Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br /> maintained in accordance with manufacturer specifications. (CBC 31366) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: 200 gpm Chlorine: 2.2 ppm Temp: ° F <br /> Cyanuric acid: 70 ppm pH: 7.4 Combined chlorine: 0.2 ppm <br /> FA0002318 PR0360407 SCO01 07/08/2020 <br /> EHD 36-01 Rev.06/30/15 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />