Laserfiche WebLink
Case Narrative C <br /> Client: Stantec Consulting Corp. Job ID: 320-59971-1 <br /> Project/Site: 7-11 No 41531 <br /> Job ID: 320-59971-1 <br /> Laboratory: Eurofins TestAmerica, Sacramento <br /> Narrative <br /> Job Narrative <br /> 320-59971-1 <br /> Comments <br /> No additional comments. <br /> Receipt <br /> The samples were received on 4/2/2020 3:55 PM;the samples arrived in good condition, properly preserved and,where required,on ice. <br /> The temperatures of the 2 coolers at receipt time were 1.6°C and 1.8°C. <br /> GC/MS VOA <br /> Method 8260B/CA_LUFTMS: Insufficient sample volume was available to perform a matrix spike/matrix spike duplicate(MS/MSD) <br /> associated with preparation batch 320-369900 and analytical batch 320-369956. <br /> Method 8260B: Internal standard (ISTD)response for the following sample was outside control limits: SB-5-10 (320-59971-13). The <br /> sample(s)was re-extracted and/or re-analyzed with concurring results,and the original set of data has been reported. <br /> Method 8260B: Insufficient sample volume was available to perform a matrix spike/matrix spike duplicate(MS/MSD)associated with <br /> preparation batch 320-369900 and analytical batch 320-369958. <br /> No additional analytical or quality issues were noted,other than those described above or in the Definitions/Glossary page. <br /> GC Semi VOA <br /> No analytical or quality issues were noted, other than those described in the Definitions/Glossary page. <br /> Organic Prep <br /> No analytical or quality issues were noted, other than those described in the Definitions/Glossary page. <br /> Eurofins TestAmerica, Sacramento <br /> Page 4 of 33 4/9/2020 <br />