Laserfiche WebLink
A J OA U I Environmental Health Department <br /> COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> FLYING J TRAVEL PLAZA t6l7 15237 N Thornton Rd, Lodi April 15, 2020 <br /> Other Violations <br /> 2010 1 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 107 CCR 2632(d), 2641(h), 2711(a) Plot plan/site map not submitted or failed to completely show where monitoring is <br /> performed. <br /> OBSERVATION: An accurate UST Monitoring Site Plan was not submitted. An accurate UST Monitoring Site Plan <br /> was not submitted. <br /> -The site map included incorrect leak detector information, showing a leak detector on 87 tank#3. No leak detector <br /> was observed on this tank. <br /> REGULATION GUIDANCE: Asite plan must be submitted identifying the locations where monitoring will be <br /> performed. The site plan must show the general layout of tanks and piping and clearly identify locations of the <br /> following equipment, if installed: 1) monitoring system control panels; 2) in-tank liquid level probes (if used for leak <br /> detection); 3) devices monitoring tank annular spaces or vault; 4) devices monitoring product piping; 5) devices <br /> monitoring fill piping; 6) devices monitoring vent piping; 7)devices monitoring vapor recovery piping; 8) devices <br /> monitoring vent/transition sumps; 9) devices monitoring under-dispenser containment; 10) line leak detectors; and <br /> 11) devices monitoring any other secondary containment areas. <br /> CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS) at <br /> http://cers.calepa.ca.gov/and upload a copy of the UST Monitoring Site Plan. <br /> This is a minor violation. <br /> 109 CCR 2637(a-d), 2712 Failed to test secondary containment, or failed to maintain test records for 36 months. <br /> OBSERVATION: Secondary containment repair testing was scheduled to be performed on 3/11/2020. Atest report <br /> has not been submitted to the EHD or the California Environmental Reporting System (CERS). No record of testing <br /> was observed on site. <br /> REGULATION GUIDANCE: Secondary containment testing is required once every 36 months. A copy of the test <br /> report must be submitted within 30 days of the test. <br /> CORRECTIVE ACTION: Immediately schedule this test and provide 48 hours notification to the EHD. <br /> This is a Class II violation. <br /> FA0012979 PR0517272 SCO01 04/15/2020 <br /> EHD 23-01 Rev.9/20/2019 Page 4 of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />