Laserfiche WebLink
auw <br /> °z SAN J OAQ U I N Environmental Health Department <br /> "iJ ; ..� COUNTY <br /> .:: Kasey Foley , REHS , Interim Director <br /> -""I iFoa�`P Greatness grows here . PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Muniappa Naidu , REHS <br /> Michael Kith , REHS <br /> Melissa Nissim , REHS <br /> January 29 , 2020 <br /> JONES COVEY GROUP , INC <br /> 9595 LUCAS RANCH ROAD # 100 <br /> RANCHO CUCAMONGA , CA 91730 <br /> Re : FLYING J TRAVEL PLAZA #617 SR0081636 <br /> 15237 N THORTON RD <br /> LODI , CA 95242 <br /> The San Joaquin County Environmental Health Department ( EHD ) has completed the review of the <br /> application for a 1 hour plan check service request to replace penetrations fittings at the 87 STP and <br /> FILL sumps , 91 STP and FILL sumps and Under Dispensers Containments sumps ( UDCs ) 7. 8 , 13 and <br /> 1 & 17 on the underground storage tank ( UST) system at the above noted address . The plan check <br /> service request has been approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ustPslgov . org for the following repairs and testing ( a 4 & hour <br /> notice is required ) . Please be aware that inspections for emergency work must be scheduled <br /> within five days of plan check service request approval . <br /> a . A secondary containment test must be performed on the under dispenser containment sump <br /> ( UDCs ) , STP and fill sumps in accordance with the manufacturers guidelines and test results <br /> submitted to the EHD within 30 days of testing . <br /> 4 . Secondary containment testing of the Sumps and UDCs is required six months after <br /> installation . Provide 48 hours notification to the EHD when test is scheduled . <br /> 5 . Any individual performing the work of a service technician must meet the following <br /> qualifications : <br /> a . Possess or be employed by a person who possesses one of several permissible valid , <br /> current contractor' s licenses issued by the Contractors State License Board ( may be issued <br /> to the installation company) , or a Tank Tester' s license issued to the individual by the State <br /> Water Board , and <br /> b . Possess or work under the direct and personal supervision of an individual physically <br /> present at the work site who possesses a valid , current California UST Service Technician <br /> certificate issued by the International Code Council ( ICC ) , and <br /> c . Possesses a valid , current certificate of training from the manufacturer( s ) of the <br /> component(s) being tested , repaired , or serviced . <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468 -3420 F 209 464- 0138 1 www . sjcehd . com <br />