Laserfiche WebLink
Appendix VI <br /> UNDERGROUND STORAGE TANK <br /> MONITORING SYSTEM CERTIFICATION FORM ( Page 1 of 6 <br /> This form must be used to document testing and servicing of underground storage tank (UST) monitoring equipment. A copy of this form <br /> must be provided to the UST owner or operator. The owner or operator must submit a copy of this form to the local agency regulating the <br /> USTs within 30 days of the date of the monitoring system certification. <br /> I . FACILITY INFORMATION <br /> CERS ID Date of Monitorinq System Certification <br /> 10180977 6/6/2019 <br /> Business Name (Same as Facility Name or DBA — Doing Business As. ) Building # <br /> Kaiser Stockton <br /> ZIP Code <br /> Business Sita Address C� <br /> 7373 West Lane Stockton 95210 <br /> II . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION i <br /> Name of Company Performinq the Certiflcation Phone # i <br /> Beishire Environmental Services , Inc . (949 ) 460-5200 j <br /> Mailing Address <br /> 25971 Towne Centre Dr. , Foothill Ranch , CA 92610 <br /> Name of UST Service Technician Performing the Certification (Print as shown on the ICC Ceitiflcation.) <br /> Jeff Badders <br /> ContractorlTank Tester License # ICC Certification # ICC Certification Expiration Date <br /> 808313 5252456 7/28/2019 <br /> Monitoring System TraInIng and Certifications Lest all applicable cedifications. Expiration Date <br /> See Attached <br /> III . RESULTS OF TESTING/SERVICING <br /> Indicate and attach the following reports if the monitorina equipment is capable of generating either Y N NA <br /> W Monitoring System Set-Up 0 Alarm History Report — — <br /> Was any monitoring equipment replaced? ❑ Q ❑ <br /> (if "Yes, " Identify the specific devices replaced and list the manufacturer and model for all replacement parts in section iV below. ) <br /> Was damage debris or liquid found inside any secondary containment systems? ❑ Q ❑ <br /> Rf "Yes " describe what was found in section iV below. ) <br /> Is all monitoring equipment operational per manufacturer's specifications? a ❑ ❑ <br /> (If Wo " describe why in section iV below. ) <br /> IV. COMMENTS <br /> if directed to use this section describe how and when the issues were or will be corrected. <br /> i <br /> I <br /> I <br /> i <br /> i <br /> V. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING . THIS TESTING <br /> I hereby certify that the equipment identified in this document was inspected/serviced in accordance with California Code of <br /> Regulatlons title 23 division 3 chapter 16 section 2638 and all information contained herein is true and accurate . Attached to <br /> this certification is information (e. a ., manufacturers' checklists monitoring system set-up , alarm history report, etc .) necessary <br /> to verify that this information and the site plan showing the layout of UST system Is complete and accurate . <br /> UST Service Technician Signature <br /> E <br />