My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
88 (STATE ROUTE 88)
>
18662
>
2300 - Underground Storage Tank Program
>
PR0505356
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 9:21:34 AM
Creation date
7/14/2020 11:28:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0505356
PE
2361
FACILITY_ID
FA0006733
FACILITY_NAME
GEORGES BP MINI MART
STREET_NUMBER
18662
Direction
N
STREET_NAME
STATE ROUTE 88
City
LOCKEFORD
Zip
95237
CURRENT_STATUS
01
SITE_LOCATION
18662 N HWY 88
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> MONITORING SYSTEM CERTIFICATION FORM (Page 2 of 6) <br /> VI . INVENTORY OF EQUIPMENT CERTIFIED <br /> A separate Monitoring System Certification Form must be prepared for each monitoring system control panel. <br /> Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed <br /> VEEDER ROOT TLS 350 329 . 01 <br /> Check the appropriate boxes to indicatespecific equipment inspected/serviced. <br /> Monitoring Device Used y Device Model # Monitorin Device Used Device Model # <br /> TANK ID : $ 7 TANK ID : 91 <br /> 8 tank number, stored product, etc. B tank number, stored product, etc. <br /> ❑x In-Tank Gauging (SW Tank) MAGI Z In-Tank Gauging (SW Tank) MAG 1 <br /> ❑x Annular Space or Vault Sensor 420 0 Annular Space or Vault Sensor 420 <br /> ❑ VPH Sensor ❑ VPH Sensor <br /> Product Piping Product Piping <br /> Z Mechanical LLD 99LD 2000 I] Mechanical LLD STP MLD <br /> ❑ Electronic LLD ❑ Electronic LLD <br /> ❑ VPH Sensor (Piping) ❑ VPH Sensor (Piping) <br /> Z Sump Sensor 2055 0 Sump Sensor 2055 <br /> ❑ VPH Sensor (Sump) ❑ VPH Sensor (Sump) <br /> Fill Piping Fill Piping <br /> ❑ VPH Sensor (Piping) ❑ VPH Sensor (Piping) <br /> ❑ Sump Sensor ❑ Sump Sensor <br /> ❑ VPH Sensor (Sump) ❑ VPH Sensor (Sump) <br /> Vent Piping Vent Piping <br /> ❑ VPH Sensor (Piping) ❑ VPH Sensor (Piping) <br /> ❑ Sump Sensor ❑ Sump Sensor <br /> ❑ VPH Sensor (Sump) ❑ VPH Sensor (Sump) <br /> Vapor Recovery Piping Vapor Recovery Piping <br /> ❑ VPH Sensor (Piping) ❑ VPH Sensor (Piping) <br /> ❑ Sump Sensor ❑ Sump Sensor <br /> ❑ VPH Sensor (Sump) ❑ VPH Sensor (Sump) <br /> Monitoring Device Used Device Model # Monitoring Device Used Device Model # <br /> TANK ID : DSL TANK ID : 89 <br /> (By tank number, stored product, e (BV tank number, stored product, etc. <br /> • In-Tank Gauging (SW Tank) MAG 1 Z In-Tank Gauging (SW Tank) MAG 1 <br /> ❑x Annular Space or Vault Sensor 420 0 Annular Space or Vault Sensor 420 <br /> ❑ VPH Sensor ❑ VPH Sensor <br /> Product Piping Product Piping <br /> ❑x Mechanical LLD 99LD 2000 N Mechanical LLD STP MLD <br /> ❑ Electronic LLD ❑ Electronic LLD <br /> ❑ VPH Sensor (Piping) ❑ VPH Sensor (Piping) <br /> ❑x Sump Sensor 2055 Z Sump Sensor 2055 <br /> ❑ VPH Sensor (Sump) ❑ VPH Sensor (Sump) <br /> Fill Piping Fill Piping <br /> ❑ VPH Sensor (Piping) ❑ VPN Sensor (Piping) <br /> ❑ Sump Sensor ❑ Sump Sensor <br /> ❑ VPH Sensor (Sump) ❑ VPH Sensor (Sump) <br /> Vent Piping Vent Piping <br /> ❑ VPH Sensor (Piping) ❑ VPH Sensor (Piping) <br /> ❑ Sump Sensor ❑ Sump Sensor <br /> ❑ VPH Sensor (Sump) ❑ VPH Sensor (Sump) <br /> Vapor Recovery Piping Vapor Recovery Piping <br /> ❑ VPH Sensor (Piping) ❑ VPH Sensor (Piping) <br /> ❑ Sump Sensor ❑ Sump Sensor <br /> ❑ VPH Sensor (Sump) ❑ VPH Sensor (Sump) <br /> ID = Identification, SW = Single-Walled, VPH = VacuumlPressumftdrostatic, LLD = Line Leak Detector <br />