My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
24572
>
2200 - Hazardous Waste Program
>
PR0531140
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/14/2020 4:49:58 PM
Creation date
7/14/2020 2:57:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0531140
PE
2221
FACILITY_ID
FA0020057
FACILITY_NAME
R S TRANSMISSION INC
STREET_NUMBER
24572
Direction
S
STREET_NAME
MACARTHUR
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
24572 S MACARTHUR
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S b N J 0 A Q U I N Environmental Health Department <br /> COUNTY <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> R S TRANSMISSION INC 24572 S MACARTHUR ,TRACY April 16, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 302 CCR 66262.34(d)(2) Failed to maintain required emergency equipment. <br /> Spill control equipment was not found on site. All facilities shall be equipped with an internal communication or alarm <br /> system, a device capable of calling outside emergency help, spill control equipment, and decontamination equipment <br /> at all times. Immediately provide spill control equipment and maintain on site. <br /> This is a minor violation. <br /> 303 CCR 66262.34(d)(2) Failed to maintain all communication or alarm systems, spill control, or decontamination <br /> equipment. <br /> The secondary containment for the two 55 gallon used oil drums had oil in the bottom of it. All facility <br /> communications or alarm systems,fire protection equipment, spill control equipment, and decontamination <br /> equipment,where required, shall be tested and maintained as necessary to assure its proper operation in time of <br /> emergency. Immediately begin this practice. <br /> This is a minor violation. <br /> 601 CCR 66262.34(d)Stored hazardous waste onsite greater than 180 days. <br /> One black metal 55 gallon drum of used paper filters was missing an accumulation start date. No disposal records <br /> for used paper filters were available during the inspection. Facilities who generate less than 1000 kg of hazardous <br /> waste per month and do not exceed 6000 kg of waste stored on site at any time may store waste on site up to 180 <br /> days. Since it cannot be determined how long the hazardous waste has been on site, immediately contact a licensed <br /> hazardous waste hauler to dispose of this waste under manifest. Submit a copy of the manifest to the EHD within 30 <br /> days. <br /> This is a Class II violation. <br /> 605 CCR 66262.34(f) Failed to completely label containers or portable tanks of hazardous waste. <br /> -One black metal 55 gallon drum of used oil was observed without accumulation start date, hazardous properties <br /> and physical state. <br /> -One blue metal 55 gallon drum of used oil did not have a hazardous waste label. The label was on the wall above it <br /> and was missing hazardous properties. <br /> -One black metal 55 gallon drum of used paper filters was missing a hazardous waste label. <br /> All hazardous waste containers shall be marked with the following information: <br /> -the words"Hazardous Waste" <br /> -name and address of generator <br /> -hazardous properties <br /> -physical state <br /> -composition (contents) <br /> -accumulation start date <br /> Immediately label these containers and ensure that all hazardous waste containers are marked with all the required <br /> information. <br /> This is a minor violation. <br /> FA0020057 PR0531140 SCO01 04/16/2019 <br /> EHD 22-01 Rev.09/27/2018 Page 4 of 5 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.