My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
192
>
2300 - Underground Storage Tank Program
>
PR0505867
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/2/2022 3:53:29 PM
Creation date
7/14/2020 4:56:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0505867
PE
2361
FACILITY_ID
FA0007059
FACILITY_NAME
H&S Energy Products,#3035
STREET_NUMBER
192
STREET_NAME
LATHROP
STREET_TYPE
Rd
City
Lathrop
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
192 Lathrop Rd
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
114
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1 ) <br /> Type of Action ❑ Installation Inspection ❑ Repair Inspection ❑x 36 Month Inspection <br /> I . FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 1 /3/2019 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) <br /> Colonial Energy <br /> Business Site Address City ZIP Code <br /> 192 Lathrop Road lathrop 195330 <br /> II . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection (Print as shown on the ICC Certification.) Phone # <br /> Anthony Reyes (916 ) 373- 1166 <br /> Contractor / Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> 617238 8293772 9/ 16/2020 <br /> Overfill Prevention Equipment Inspection Training and Certifications (List applicable certifications.) <br /> OPW UST Phase 1 EVR Tech#103920 <br /> III . OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method ❑x Manufacturer Guidelines (Specify) : <br /> Used : OPW Install & Maintenance Guidelines <br /> ❑ Industry Code or Engineering Standard (Specify): <br /> ❑ Engineered Method (Specify): <br /> Attach the inspection procedures and all documentation required to determine the results. # of Attached Pages <br /> TANK ID : (By tank number, stored product, etc.) 87 Master 87 Slave 91 Gasoline Diesel <br /> What is the tank inside diameter? (Inches) 1 13 . 75 113 . 75 113 . 75 110 . 75 <br /> Is the fill piping secondarily contained? ❑x Yes ❑ No ❑x Yes ❑ No R Yes ❑ No ❑x Yes [I No <br /> Is the vent piping secondarily contained? ❑ Yes [j] No ❑ Yes E] No ❑ Yes x❑ No ❑ Yes [j] No <br /> Overfill Prevention Equipment Manufacturer(s) OPW OPW OPW OPW <br /> What is the overfill prevention equipment response ❑x Shuts Off Flow ❑x Shuts Off Flow ❑x Shuts Off Flow ❑x Shuts Off Flow <br /> when activated? <br /> (Check all that apply.) ❑ Restricts Flow ❑ Restricts Flow ❑ Restricts Flow ❑ Restricts Flow <br /> ❑ AN Alarm ❑ AN Alarm ❑ AIV Alarm ❑ AN Alarm <br /> Are flow restrictors Installed on vent piping? ❑ Yes ❑x No ❑ Yes ❑Q No ❑ Yes ❑x No ❑ Yes ❑x No <br /> At what level in the tank is the overfill prevention set <br /> to activate? (Inches from bottom of tank.) 99 . 75 102 . 125 99 . 875 97 . 625 <br /> What is the percent capacity of the tank at which the <br /> overfill prevention equipment activates? 92 % 94% 92 % 920%lo <br /> Is the overfill prevention in proper operating condition ❑x Yes ❑x Yes ❑x Yes ❑x Yes <br /> to respond when the substance reaches the <br /> appropriate level? ❑ No (Specify in V.) ❑ No (Specify in V.) ❑ No (Specify in V.) ❑ No (Specify in V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results r ❑x Pass ❑ Fail ❑x Pass E] Fail ❑x Pass ElFail 21 Pass El Fail <br /> V. COMMENTS <br /> Any items marked `Fail' must be explained in this section. Any additional comments may also be provided here. <br /> VI . CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations , Title 23, <br /> Division 3 , Chapter 16, Section 2637.2 and all the information contained herein is accurate . <br /> UST Service Technician Signature -- ;, <br /> If the facility has more components than this form accommodates, additional copies of this page may be attached. <br /> CERS = California Environmental Reporting System, ID = Identification, UST = Underground Storage Tank, ICC = International Code Coundl, AN = Audible and Visual l.� <br />
The URL can be used to link to this page
Your browser does not support the video tag.