COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VAN RYN
>
1339
>
2200 - Hazardous Waste Program
>
PR0535473
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/15/2020 12:36:24 PM
Creation date
7/15/2020 10:13:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0535473
PE
2220
FACILITY_ID
FA0019210
FACILITY_NAME
MANTECA WELL #24
STREET_NUMBER
1339
STREET_NAME
VAN RYN
STREET_TYPE
AVE
City
MANTECA
Zip
95337
APN
22404046
CURRENT_STATUS
01
SITE_LOCATION
1339 VAN RYN AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A8L1471 <br /> E3-=n-K General: Heavy Metals <br /> ASSOCIATES <br /> Certificate of Analysis <br /> Notes: <br /> The Chain of Custody document and Sample Integrity Sheet are part of the analytical report. <br /> Any remaining sample(s)for testing will be disposed of according to BSK's sample retention policy unless other arrangements are made in <br /> advance. <br /> All positive results for EPA Methods 504.1 and 524.2 require the analysis of a Field Reagent Blank(FRB)to confirm that the results are not <br /> a contamination error from field sampling steps.If Field Reagent Blanks were not submitted with the samples,this method requirement has <br /> not been performed. <br /> Samples collected by BSK Analytical Laboratories were collected in accordance with the BSK Sampling and Collection Standard Operating <br /> Procedures. <br /> J-value is equivalent to DNQ(Detected,not quantified)which is a trace value. A trace value is an analyte detected between the MDL and the <br /> laboratory reporting limit.This result is of an unknown data quality and is only qualitative(estimated).Baseline noise,calibration curve <br /> extrapolation below the lowest calibrator,method blank detections,and integration artifacts can all produce apparent DNQ values,which <br /> contribute to the un-reliability of these values. <br /> (1)-Residual chlorine and pH analysis have a 15 minute holding time for both drinking and waste water samples as defined by the EPA and <br /> 40 CFR 136.Waste water and ground water(monitoring well)samples must be field filtered to meet the 15 minute holding time for dissolved <br /> metals. <br /> Summations of analytes(i.e.Total Trihalomethanes)may appear to add individual amounts incorrectly,due to rounding of analyte values <br /> occurring before or after the total value is calculated,as well as rounding of the total value. <br /> RL Multiplier is the factor used to adjust the reporting limit(RL)due to variations in sample preparation procedures and dilutions required for <br /> matrix interferences. <br /> Due to the subjective nature of the Threshold Odor Method,all characterizations of the detected odor are the opinion of the panel of <br /> analysts. The characterizations can be found in Standard Methods 2170B Figure 2170:1. <br /> The MCLs provided in this report(if applicable)represent the primary MCLS for that analyte. <br /> Definitions <br /> mg/L: Milligrams/Liter(ppm) MDL: Method Detection Limit MDA95: Min.Detected Activity <br /> mg/Kg: Milligrams/Kilogram(ppm) RL: Reporting Limit:DL x Dilution MPN: Most Probable Number <br /> pg/L: Micrograms/Liter(ppb) ND: None Detected at RL CFU: Colony Forming Unit <br /> pg/Kg: Micrograms/Kilogram(ppb) pCi/L: PicoCuries per Liter Absent: Less than 1 CFU/100mLs <br /> %: Percent RL Mult: RL Multiplier Present: 1 or more CFU/100mLs <br /> NR: Non-Reportable MCL: Maximum Contaminant Limit <br /> Please see the individual Subcontract Lab's report for applicable certifications. <br /> BSK is not accredited under the NELAP program for the following parameters: <br /> Antimony,WET Arsenic,WET Barium,WET <br /> Beryllium,WET Cadmium,WET Chromium,WET <br /> Cobalt,WET Copper,WET Lead,WET <br /> Mercury,WET Molybdenum,WET Nickel,WET <br /> Selenium,WET Silver,WET Thallium,WET <br /> Vanadium,WET Zinc,WET <br /> The results in this report apply to the samples analyzed in A8L1471 FINAL 12272018 1717 <br /> accordance with the chain of custody document.This <br /> analytical report must be reproduced in its entirety. <br /> www.BSKAssociates.com Page 14 of 18 <br />
The URL can be used to link to this page
Your browser does not support the video tag.