Laserfiche WebLink
1 <br /> SGENERAL INFORMATION <br />' l Obtain an EPA Site Number from the Department of Health Services (916) 324-1781 for temporary <br /> hazardous waste removal activities associated with underground storage tank (UST) removals <br />' 2 Disposal Information Public Health Services Tracking Sheet shall accompany each tank removed <br /> from site Tank(s)will be issued an identification number which PHS-EHD's representative will note <br />' on the Tank Tracking Sheet Contractor will affix same identification number onto tank end using <br /> fluorescent spray paint Contaminated tanks and/or piping are to be transported under Hazardous <br /> Waste Manifest by a state registered hazardous waste hauler <br /> I 3 Contractor to Provide Combustible/Flammable gas detector (to verify the Lower Explosive Limit <br /> (LEL) atmosphere and oxygen level of tank prior to lifting from excavation), adequate number(s) and <br /> appropnate type(s) of fire extinguisher(s),barriers to secure the area as necessary to minimize traffic <br /> and pedestrian interference, and fluorescent spray paint to affix tank identification numbers It shall <br /> be the project manager's responsibility for compliance with all health & safety regulations and <br /> requirements,which shall be strictly adhered to at all times during the course of the closure activities <br /> 4 The PHS-EHD permit shall be on site during tank excavation and removal <br /> 5 Any changes in this document shall be approved by PHS-EHD prior to initiating work. <br /> I6 Closure-In-Place If Closure-in-Place Is the suggested method of abandonment, complete form <br /> EH 23 039 and submit written approval from the local Fire Department <br /> 7 Temporary Closure If Temporary Closure is the suggested method of abandonment, complete <br /> form EH 23 046 and submit written approval from the local fire Department <br /> 8 The following documentation shall be submitted within 30 days of the tank removal <br /> date: <br /> a) Analytical results, mailed directly from laboratory to PHS-EHD,including a chain of custody <br /> b) Tank Tracking Record Sheet(s) and/or Tank Hazardous Waste Manifests) <br />' c) Hazardous Waste Manifests for piping, rinsate, residual fuel, or waste oil receipt, <br /> I d) Submit the backfill excavation certificate as requtred by San Joaquin County and the <br /> Incorporated City Building Departments This report will be referred to the appropriate <br /> agency for their review. <br /> A site which has had UST(s) removed, shall not be considered for final closure until the above: Items <br /> are submitted for review. <br /> i <br /> EH 23 040 (Revised 7-10-92) Page 2 <br />