Laserfiche WebLink
J. <br /> APPI ed GeoSystems 43255 ,Mission Blvd. Suite B Fremont, CA 94539 1415',651-1906 <br /> RECORD OFANALYSIS <br /> Date 7-22-87 <br /> Applied GeoSystems <br /> 43255 -Mission Blvd. <br /> Fremont, CA. 94539 <br /> Attention: Andrew P. Lush <br /> Date Received: 7-22-87 Laboratory# 87075088 <br /> Date Analyzed: 7-16-87 <br /> Procedure: <br /> The soil samples referenced on the attached Chain-of-Custody were <br /> analyzed for Total Volatile Hydrocarbons (TVH) by EPA method <br /> 8020. The samples were concentrated on a Tekmar LSC-2 and ALS <br /> automatic sampler prior to injecti n into a 5890 Hewlett Packard <br /> gas chromatograph fitted with a Flame Ionization detector (FID) . <br /> The limit of detection for these samples is 0. 05 <br /> milligrams/kilogram (parts per million = ppm) . <br /> The results are presented in the table below: <br /> OTAL VOLATILE <br /> SAMPLE SITE HYDROCARBONS <br /> S-P1(ABCD) 87036-2 126. 06 <br /> S-P2(AB) 87036-2 105 .67 <br /> S-P3 (AB) 87036-2 6 . 69 <br /> Results in milligrams/kilogram (parts per million = ppm) . <br /> t/ <br /> Tia Tran, Chemist <br /> Applied GeoSystems is a State of California, Department of Health <br /> Services Certified Hazardous Waste Testing Laboratory (No. 153 ) . <br />