Laserfiche WebLink
„,,. ;mr - °✓�� -,u�'P re4ro ::'F"c �tsiY 'Y= .ryRti t i7,.wyW. !j <br /> n, 7 r.�'.tsy��r'”1 w4�[r'rF NI`ri '-.,A_C:'�1 • sk,-..�YS h 7: 4F'is�:4E..ir 4r 5 91�Y1F rr y f°.-se .rvn -$, r,..-'`-1 -A,v. ,____,3 .''. <br /> 'w H yrw i �s '. "t <br /> J <br /> V� <br /> I'f2C7C;f?])URI S FOR STARTUP: <br /> 1. Read arul familiarize: YOU <br /> with the inslrunlcnZ's operating instntctint+s• Don appropriate <br /> as prescribed in the D1 RS tlealhb anti S:lfcly Pfasr for the pruScct. <br /> 2 Check the Fl)NCI'ION switch yrs the control ]),incl to make sure it iS in the OFi' positinn. <br /> ti t'avist the catineculr <br /> Altach the probe to the readout unit. Match the alignlncat key, an <br /> clockwise until a di stinal locking is fell. <br /> 3. 'Turn the FUNCTION switch to the 13A]-I'ERY CIIGCK position. Chcck that thr: indicator <br /> reads within or beyond the green battery arc oil the sc 1c plate. if the indicator is below the <br /> green are,or if tits: red LII-comes on, the baucry must be c15;5rgid belt+sc using, 13e ccrtaui <br /> Ili:+t an cxtm, charged battery is on supply. <br /> urn the FUNCTION switch to the STANDBY position anti rotate the <br /> 4. 1'o zero the instrument,t <br /> :C.LRO P0TFNI'IOML`I'];IZ until the meter re.tds zero. W:lil 15 to 2l)secoMIS to cosrfirm Mutt <br /> the zero adjustment is st:Mlle; if not,then readjust. <br /> S. Check to sce that the SPAM POTENTIOMETER is sct at ilia appropriate setting for the pi ohe <br /> 6cing used (5.) for }.5� cV 1lrobc, 9.8 for 10.2 cV, and 5.0 for 11.7 eV). <br /> G. Set the I�UNC1'SON switch to lire ticsircti Illrm ranSc. A violet glow dont the UV tight source <br /> should be obscrvablc:It the sample inlet of the probe/scnsar unil. (Do not look directly at the <br /> glow.since eye damage could resell.) <br /> r. Listen for the fan operafion to verify f:rn function. <br /> S. Check the instrument with an organic point source, such as a "Itrtgic marker",hefol—Survey to <br /> verify InStrllgicilt ftlllctlon. <br /> y. Survey the area for orgatlic vapors. "I-1-te lip of lilt; probe should tic as bear its possible to the <br /> monitored source. If' any response occurs, note the: fincJin s in Field ld Log- if tilt re is I:o <br /> response, record "NIR" in the hick) Lou;. <br /> PROCF-DURC:S FOIL SHUTDOWN: <br /> 1. 'Turn the FUNCCION switch to Oh1-1. <br /> 2. Disconnect tilt:plolbe corinectar. <br /> 3. I'lacc tLe instrument on the charger. <br /> PROC EDURI S I-OR CALII312NOON: <br /> For OMNI calibration canisters without.rct;uia�s�rs= <br /> ] Run through sSarlup praccdures. <br /> 2. FN a sampling bag with OVM calibration gas of known contents. <br /> A-23 <br />