Laserfiche WebLink
T <br /> • S4GiATES INC. <br /> QUALITY ASSURANCE I QUALITY CONTROL (QA/QC)PROCEDURES <br /> Field Procedures <br /> To prevent contamination of the samples and/or cross-contamination of monitoring wells ATC personnel <br />' adhere to the following procedures in the field <br /> • New, clean pair of appropriate disposable gloves is dawned prior to sampling each well <br />' • Wells are gauged and purged in the expected order of increasing degree of contamination based on <br /> historical analytical results <br /> • All purging equipment will be thoroughly decontaminated between each well using the procedures <br /> previously described at the beginning of this section <br /> • During sample collection for volatile organic analysis,the amount of air passing through the sample <br /> is minimized Thus helps prevent the air from stnpping the volatiles from the groundwater Sample <br /> bottles are filled by slowly running the sample down the side of the bottle until there is a convex <br /> meniscus over the mouth of the bottle The lid is carefully screwed onto the bottle such that no air <br /> bubbles are present within the bottle If a bubble is present,the cap is removed and additional water <br /> is added to the sample container After resealing the sample container, if bubbles still are present <br /> inside,the sample container is discarded and the procedure is repeated with a new container <br /> Sample Central <br /> Laboratory and field handling procedures may be monitored, if required by the client or local regulatory <br /> agency, by including quality control (QC) samples for analysis with the groundwater samples Examples of <br />' different types of QC samples are as follows <br /> • Trip blanks are prepared at the analytical laboratory, by laboratory personnel to check handling <br /> procedures while in the field, as required by site conditions and local regulations Trip blanks are <br />' transported to the project site in the same manner as the laboratory-supplied sample containers to be <br /> filled They are not opened, and are returned to the laboratory with the samples collected Trip <br /> blanks are analyzed for purgable organic compounds <br /> • Equipment blanks are prepared in the field to determine if decontamination of field sampling <br /> equipment has been effective, as required by site conditions and local regulations The sampling <br /> equipment used to collect the groundwater samples is rinsed with distilled water that is then <br />' decanted into laboratory-supplied containers The equipment blanks are transported to the <br /> laboratory, and are analyzed for the same chemical constituents as the samples collected at the site <br /> • Duplicates (split samples) are collected at the same time that the standard groundwater samples are <br /> being collected and are analyzed for the same compounds in order to check the reproducibility of <br /> laboratory data They are typically only collected from one well per sampling event, as required by <br /> site conditions and local regulations The duplicate is assigned an identification number that will <br />' Apt.associate it with the source well <br /> Gene ,trip blanks and field blanks check field handling and transportation procedures Duplicates check <br /> ab <br /> }�umdures The configuration of QC samples is determined by ATC depending on site <br /> con itions aad regulatory requirements <br /> 1 <br />