My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0008568
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
2537
>
3500 - Local Oversight Program
>
PR0545857
>
ARCHIVED REPORTS_XR0008568
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/15/2020 9:06:49 PM
Creation date
7/15/2020 3:00:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0008568
RECORD_ID
PR0545857
PE
3528
FACILITY_ID
FA0005147
FACILITY_NAME
E-Z FOOD
STREET_NUMBER
2537
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
11914035
CURRENT_STATUS
02
SITE_LOCATION
2537 WATERLOO RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
73
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br /> SOCIIN( II <br /> GROUNDWATER MONITORING AND SAMPLING PROCEDURES <br />' (Includes No-Purge Sampling) <br />' Groundwater Morutorine and Decontamination Method <br /> Prior to beginning, a decontamination area is established Decontamination procedures consist of scrubbing <br /> down-well equipment in a Lnquidnoi� solution wash (or equivalent degreasing compound), and rinsing in <br />' potable water and a final rinse of de-ionized (or distilled) water before and after each well Any non- <br /> dedicated down-well equipment is decontaminated prior to use on site <br />' <br /> Prior to purging and sampling a well, the static water level is measured to the nearest 0 01 feet with an <br /> electronic interface probe and/or water level meter Depth to bottom is typically measured every quarterly <br /> event The water level meter and tape will be decontaminated between each well If floating phase- <br /> separated hydrocarbons (PSH) are suspected or previously confirmed, an electronic interface probe is used <br />' to measure the well fluids to the nearest 0 01 feet PSH may altematively be measured using a clear, open- <br /> ended product bailer, and the thickness is measured to the nearest 0 01 feet in the bailer Any monitoring <br /> well containing a measurable thickness of PSH before or during purging is not additionally purged and no <br /> sample is collected from that well Wells containing hydrocarbon sheen are sampled unless otherwise <br /> specified by the project manager Field observations such as well integrity as well as water level <br /> measurements and PSH thickness are recorded in the field <br />' Well Purging <br /> When well purging is required, each monitoring well to be sampled is purged using, a truck-mounted <br />' vacuum pump, a polyvinyl chloride (PVC) bailer or a submersible pump Physical parameters (pH, <br /> temperature, and conductivity) of the purge groundwater are monitored during purging activities to assess if <br /> the water sample collected is representative of the aquifer If required,parameters such as dissolved oxygen, <br /> turbidity, salinity etc are also measured Samples are considered representative if parameter stability is <br />' achieved Stability is defined as a change of less than 0 25 pH units, less than 10%change in conductivity in <br /> micro mhos, and less than 10 degree centigrade (1 8 degrees Fahrenheit) change in temperature Parameters <br /> are measured in a discreet sample decanted from the hailer separately from the rest of the purge <br />' groundwater Parameters are measured during purging, initially, and at volume intervals of one well or <br /> borehole volume (dependent on local regulations) Purging continues until the required well or borehole <br /> volumes have been removed, until the well completely dewaters, or until measured parameters stabilize as <br />' indicated above When wells dewater or demonstrate a slow recharge, wells may be sampled although <br /> fewer than required volumes have been removed Well purging information is recorded on the Purge Data <br /> sheet All meters used to measure parameters are calibrated daily Purge water is sealed, labeled, and stored <br /> on site in DO T-approved 55-gallon drums After being chemically profiled,the water is transported to an <br /> appropriate disposal facility by a licensed waste hauler <br /> Groundwater Sample Collection <br /> After purging, groundwater samples are collected after at least 80% of its static water level is recovered in <br /> the well If recharge is extremely slow, the well is allowed to recharge until sufficient volume has <br /> accumulated for sample collection No-purge groundwater samples are collected when prior approval <br />' by the lead regulatory agency has been permitted When no-purge samples are collected the same <br /> procedures are followed excluding well purging. All groundwater samples are collected using <br /> polyethylene disposable bailers attached with new, clean string or rope Groundwater samples being <br /> analyzed for compounds most sensitive to volatilization are collected first Groundwater samples are placed <br /> in appropriate laboratory-supplied containers, labeled, documented on a chain of custody form and <br /> preserved on ice in a cooler for transport to a state-certified analytical laboratory After collection, all <br />' samples are stored in a chilled cooler and refrigerated to approximately four (4) degrees Celsius while a <br /> laboratory representative transports the samples to their facility Analytical detection limits match or <br /> surpass standards required by relevant local or regional guidelines <br /> r <br />
The URL can be used to link to this page
Your browser does not support the video tag.