ARCHIVED REPORTS_XR0008575
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
2537
>
3500 - Local Oversight Program
>
PR0545857
>
ARCHIVED REPORTS_XR0008575
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/15/2020 4:45:53 PM
Creation date
7/15/2020 3:01:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0008575
RECORD_ID
PR0545857
PE
3528
FACILITY_ID
FA0005147
FACILITY_NAME
E-Z FOOD
STREET_NUMBER
2537
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
11914035
CURRENT_STATUS
02
SITE_LOCATION
2537 WATERLOO RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br />' 5 6 Groundwater Monitoring and Sampling <br /> Due to the recent increase in groundwater elevation, depth to water at the site is currently above the <br />' screened Intervals for wells MW-1 through MW-8 Therefore, these wells will not be used for <br /> groundwater monitoring purposes ATC proposes to gauge, purge and collect groundwater samples from <br /> groundwater monitor wells MW-9 through MW-17 and vapor extraction wells SVE-1 through SVE-3 on a <br />' quarterly basis for a year <br /> Assuming that phase separated hydrocarbons (PSH) are not present, static water levels in each well will <br /> be measured, each well will be purged of an appropriate volume of groundwater, allowed to recharge, and <br /> a representative groundwater sample will be collected from the well in general accordance with ATC's <br />' Standard Operating Procedure - Groundwater Monitor Well Purging and Sampling, which is included in <br /> Appendix A Quarterly groundwater monitoring reports will be prepared and submitted to the SJC The <br /> reports will summarize the quarterly groundwater elevation measurements, calculated groundwater <br /> gradient and flow direction and analytical results of the quarterly sampling <br />' 5.7 Analytical Testing <br /> Analyses of a representative sample of the drill cuttings and groundwater samples will be performed by a <br />' State-certified laboratory All drill cuttings will be collected in DOT-approved 55-gallon drums and will <br /> remain on-site pending proper disposition Soil cuttings will be managed in accordance with the ACHCSA <br /> Regulations <br /> lieQuality Assurance and Quality Control (QA/QC) procedures, sample preservation, apparatus required, <br /> and analyses performed will be per 1)A A C R9-14-601 through -617, 2) U S EPA Document EPA-600, <br />' "Methods for Chemical Analysis for Water and Wastes" dated July 1982, and 3) U S EPA document SW- <br /> 846, 3rd Edition, "Test Methods for Evaluating Solid Waste Physical Chemical Methods", dated <br /> November 1986 <br /> Select soil and groundwater samples will be analyzed for total petroleum hydrocarbons characterized as <br /> gasoline (TPHg), benzene, toluene, ethylbenzene, total xylenes (BTEX), methyl-tertiary-butyl ether <br />' (MTBE), tert-amyl methyl ether (TAME), tert-butyl alcohol (TBA), di-isopropyl ether (DIPE), and ethyl- <br /> tert-butyl ether(ETBE) in accordance with Environmental Protection Agency (EPA) Test Method 8260B <br /> All groundwater samples will be additionally analyzed for ethanol, methanol, 1,2-dichlroethane, and <br /> ethylene dibromide in accordance with EPA Test Method 8260 <br /> 5.8 Vapor Extraction Pilot Test <br /> A vapor extraction pilot test (VEPT) will be conducted to evaluate the feasibility of utilizing this <br /> technology for remediation of the hydrocarbon-impacted vadose zone soil Additionally, the pilot test <br /> data can be used to design the appropriate soil and groundwater remediation system <br /> EZ 100966SAFSWP ATC Associates Inc <br /> S%EZ Serve\EZ 1009661Reports\I00966SAFSWP ATC Project No 43 25827 0026 <br /> 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.