Laserfiche WebLink
Environmental Health Department <br />Time In: <br /> 1:00 pm <br />12:00 pm <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: (209) 956-3400 Owner/Operator: OCONNOR WOODS HOUSING CORP <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />Address: 3400 WAGNER HEIGHTS , STOCKTON 95209 <br />Date: 08/08/2018Name of Facility: OCONNOR WOODS RETIREMENT COMMUNITY <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #3 Safety Signs <br />OBSERVATIONS: Safety signs need to include the address of the facility so that in an emergency first responders know <br />where to go immediately. Provide a sign that is easily readable by the next routine inspection. <br />CALCODE DESCRIPTION: Pool operator shall keep safety signs well maintained. (CCR 65535) Safety signs shall have clearly legible <br />letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall, pole, gate, or similar <br />permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 3120B) <br /> #8 Pool and Deck Lighting <br />OBSERVATIONS: Both lights did not turn on in the pool, they could be on a light detection sensor. Ensure that the pool <br />lights can be turned off by a GFI circuit breaker when ON. <br />CALCODE DESCRIPTION: Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br />pool. When a pool is used at night, pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br />not operational, the pool operator shall post a sign in 4-inch letters stating "NO USE OF POOL ALLOWED AFTER DARK" and shall <br />secure the pool area and not permit any use of the pool after dark. (3115B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F 55 <br />7.5 <br />3.8 <br />45 <br /> 91.50 <br />Combined chlorine:ppm0.4 <br />NOTES <br />Influent: 21 psi <br />Effluent: 12 psi <br />The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br />Safety Code. If a reinspection is required, fees will be assessed at the current hourly rate. <br />Received by: Name and Title: <br />EH Specialist:Phone:(209) 468-3442 <br />Nancy, Director <br />AARON GOODERHAM <br />Page 1 of 1EHD 36-01 Rev. 06/30/15 Swimming Pool OIR <br />FA0001943 PR0360603 SC001 08/08/2018 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjcehd.com