My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FLAG CITY
>
14931
>
2300 - Underground Storage Tank Program
>
PR0506221
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2020 1:45:27 PM
Creation date
7/15/2020 4:53:12 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0506221
PE
2361
FACILITY_ID
FA0007287
FACILITY_NAME
LODI OIL INC ARCO #83680
STREET_NUMBER
14931
Direction
N
STREET_NAME
FLAG CITY
STREET_TYPE
BLVD
City
LODI
Zip
95242
CURRENT_STATUS
01
SITE_LOCATION
14931 N FLAG CITY BLVD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for LODI OIL INC ARCO #83680 as of May 06 , 2020 . <br /> Open violations from May 09, 2019 inspection <br /> Violation #209 - Failure to conduct the designated UST operator visual inspection at least once every 30 <br /> days . <br /> The designated operator failed to check and note all required items on the visual inspection reports . The incorrect <br /> and missing information included the following from the inspection reports : <br /> -Section V was filled out by the designated operator and did not include the corrective actions that will be taken by <br /> the owner/operator. <br /> - Incorrect monitoring system certification and spill container test dates were listed . <br /> -Section V was left blank . <br /> -Reports were unsigned by the owner/operator . <br /> -The designated operators , including Brian Roth , are indicating that they are looking inside fill sumps ; Mr. Roth <br /> stated that fill sumps could not be opened during the testing , have never been opened by him , and appear as if they <br /> have not been opened in over a year. <br /> -The N and NA answers were not included in section III. <br /> -CERS ID was left blank . <br /> -The question regarding UDC sensor locations was left blank . <br /> -The question regarding sump sensor locations was left blank . <br /> -Overfill test information was left blank . <br /> -The reports incorrectly mark that all follow up to previously reported issues were completed and list repeat issues in <br /> Section III . <br /> During the visual inspection , the designated operator shall check that all required testing and maintenance for the <br /> UST system have been completed and shall check all required items on the report. Ensure that designated <br /> operators performing visual inspections at this facility are including all of the required information on the reports . <br /> The designated operator failed to document all the alarms from the attached alarm histories on the designated <br /> operator inspection reports and failed to check that they were responded to appropriately. The missing alarms <br /> include : <br /> -L2 ( UDC 3/4) fuel alarms on 2/26/19 and 1 /16/19 <br /> During the inspection , the designated operator shall review the alarm history since the previous inspection , check <br /> that each alarm was documented and responded to appropriately, and attach a copy of the alarm history with <br /> documentation taken in response to any alarms to the report . Ensure that designated operators performing <br /> inspections at this facility are including all of the required information on the reports . <br /> A designated operator inspection for the following months was performed more than 30 days : <br /> -Conducted 11 /9/18 , next conducted 12/10/ 18 (31 days) <br /> -Conducted 12/10/18 , next conducted 1 /16/ 19 ( 37 days) <br /> -Conducted 3/5/19 , next conducted 4/5/ 19 (31 days) <br /> The designated operator visual inspections shall be conducted within 30 days or less of the previous inspection . <br /> Ensure that all designated operator inspections are performed within the required time frames . <br /> ❑ This violation was corrected ❑ This violation will be corrected by ( date) : <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : <br /> Page 4 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.