COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4943
>
2300 - Underground Storage Tank Program
>
PR0506488
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:16 PM
Creation date
7/16/2020 8:57:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0506488
PE
2361
FACILITY_ID
FA0007458
FACILITY_NAME
7-ELEVEN INC #32190
STREET_NUMBER
4943
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
CURRENT_STATUS
01
SITE_LOCATION
4943 S HWY 99
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
95
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> RESPONSE PLAN - PAGE I (One form er facilR <br /> xol . <br /> TYPE ❑ 1 . NEW PLAN ® 2. CHANGE OF INFORMATION <br /> l . s <br /> FACILITY ID # (Agency Use Onl)) I. FACILITY INFORMATION <br /> 3. <br /> BUSINESS NAME (Same as FACILITY NAME) <br /> 7 -Eleven Store # 32190 103. BUSINESS SITE CITY 104. <br /> BUSINESS SITE ADDRESS <br /> 4943 S . STATE RT . 99 Stockton <br /> II: SPILL CONTROL AND CLEANUP METHODS <br /> This plan addresses unauthorized releases from UST systems and supplements the emergency response plans and procedures in the facility's Hazardous Materials <br /> Business Plan (HMBP). <br /> ➢ If safe to do so, facility personnel will take immediate measures to control or stop any release (e.g., activate pump shut-oft, etc. ) and, if necessary, safely remove <br /> remaining hazardous material from the UST system. <br /> ➢ Any release to secondary containment will be pumped or otherwise removed within a time consistent with the ability of the secondary containment system to <br /> contain the hazardous material, but not greater than 30 calendar days, or sooner if required by the local agency . Recovered hazardous materials, unless still suitable <br /> for their intended use, will be managed as hazardous waste. <br /> )o Absorbent material will be used to contain and clean up manageable spills of hazardous materials. Absorbent material which has become too saturated to at <br /> effective or which is no longer intended for use will be managed as hazardous waste unless a waste determination in accordance with 22 CCR §66262. 11 finds that <br /> it is non-hazardous. Used absorbent material , reusable or waste, will be stored in a properly labeled and sealed container. Waste material shall be disposed of <br /> appropriately. <br /> ➢ Facility personnel will determine whether any water removed from secondary containment systems, or from clean-up activity, has been in contact with any <br /> hazardous material . If the water is contaminated, it will be managed as hazardous waste unless a hazardous waste determination in accordance with 22 CCR <br /> §66262. 11 finds that it is nonhazardous. If the water has a petroleum sheen (i.e. , rainbow colors), it is contaminated. A thick floating petroleum layer may not <br /> necessarily display rainbow colors. Water (hazardous or non-hazardous) from sumps, spill containers, etc . will not be disposed to storm water systems. <br /> ➢ We will review secondary containment systems for possible deterioration if any of the following conditions occur: <br /> 1 . Hazardous material in contact with secondary containment is not compatible with the material used for secondary containment; <br /> 2 . Secondary containment is prone to damage from any equipment used to remove or clean up hazardous material collected in secondary containment; <br /> 3 . Hazardous material, other than the product/waste stored in the primary containment system, is placed inside secondary containment to treat or neutralize <br /> released product/waste, and the added material or resulting material from such a combination is not compatible with secondary containment. <br /> III. SPILL CONTROL AND CLEAN-UP EQUIPMENT <br /> PERIODIC MAINTENANCE: Spill control and clean-up equipment kept permanently on-site is listed in the facility' s Hazardous Materials Business Plan. This <br /> equipment is inspected at least monthly, and after each use, supplies are replenished as needed. Defective equipment is repaired or replaced as necessary . <br /> EQUIPMENT NOT PERMANENTLY ON-SITE, BUT AVAILABLE FOR USE IF NEED7R22. <br /> l i n licable) <br /> EQUIPMENT LOCATION AVAILABILI'T'Y <br /> R10. <br /> R30. <br /> x11 . <br /> R31 . <br /> R12. <br /> R32. <br /> R13. <br /> R23. R33. <br /> R14. <br /> R24. R34. <br /> RIS. <br /> R25. R35. <br /> IV RESPONSIBLE PERSONS <br /> THE FOLLOWING PERSON(S) IS/ARE RESPONSIBLE FOR AUTHORIZING ANY WORK NECESSARY UNDER THIS RESPONSE PLAN: Rso. <br /> NAME R40 TITLE <br /> GILL, JIVTESH S . Franchisee <br /> R41 , TITLE R51 . <br /> NAME Regional Compliance Specialist <br /> Ethan Valbur R52. <br /> NAME R42. TITLE <br /> Regional Compliance Manager <br /> Stephen Boyd <br /> R53. <br /> R43. TITLE <br /> NAME <br /> V. MONITORING INDICATORS <br /> IF MONITORING INDICATES A POSSIBLE UNAUTHORIZED RELEASE, STEPS TO VERIFY THE RELEASE WILL BE MADE AS FOLLOWS : Rao. <br /> ® I . ADDITIONAL SYSTEM TESTING OR DATA COLLECTION ® 2. INSPECTION BY QUALIFIED PERSONS [13, RECALIBRATION OF EQUIPMENT R61 . <br /> ❑ 99. OTHER (Specify): <br /> UN-02213 - I/705 <br /> www. unidoes. org Rev. 04/02/08 <br />
The URL can be used to link to this page
Your browser does not support the video tag.