Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> MONITORING SYSTEM CERTIFICATION FORM (Page 1 of 6) <br /> This form must be used to document testing and servicing of underground storage tank(UST)monitoring equipment. A copy of this form <br /> must be provided to the UST owner or operator. The owner or operator must submit a copy of this forth to the local agency regulating the <br /> USTs within 30 days of the date of the monitoring system certification. <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Monitoring System Certification <br /> 10182243 03/12/2020 <br /> Business Name(Same as Facility Name or DBA—Doing Business As.) Building# <br /> MAIN STREET ARCO AM PM <br /> Business Site Address City ZIP Code <br /> 1100S Main St Manteca 95337 <br /> 11. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of Company Performing the Certification Phone# <br /> Diamond Petroleum Services, Inc. (925)470 - 0803 Ext. <br /> Mailing Address <br /> 3619 King Ct. Antioch, CA 94509 <br /> Name of UST Service Technician Performing the Certification(Print as shown on the 1CC Certification.) <br /> Guadalupe Sanchez <br /> Contractor/Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> 1005444 5250451 04/05/2021 <br /> Monitoring System Training and Certifications List all applicable certifications. Expiration Date <br /> Veeder Root A30138 10/05/2021 <br /> VMI Va orless LDT-890 Tester#4068 06/12/2021 <br /> III. RESULTS OF TESTING/SERVICING <br /> Indicate and attach the following reports if the monitoring equipment Is capable of generating either. Y N NA <br /> ®Monitoring System Set-up ®Alarm History Report <br /> Was any monitoring equipment replaced? <br /> (If"Yes,"identify the specific devices replaced and list the manufacturer and model for all replacement parts in section 1V below.) <br /> Was damage,debris,or liquid found inside any secondary containment systems? <br /> (If`Yes,"describe what was found in section IV below.) 19 11 <br /> Is all monitoring equipment operational per manufacturer's specifications? <br /> (if'No,"describe why in section IV below.) <br /> IV. COMMENTS <br /> If directed to use this section,describe how and when the issues were or will be corrected. <br /> APR <br /> ENTAL <br /> nFpARTMEN-1 <br /> V. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> I hereby certify that the equipment identified in this document was inspected/serviced in accordance with California Code of <br /> Regulations,title 23,division 3,chapter 16,section 2638 and all information contained herein is true and accurate. Attached to <br /> this certification Is Information(e.g.,manufacturers'checklists,monitoring system set-up,alarm history report,etc.)necessary <br /> to verify that this information and the site plan showing the layout pf UST system is complete and accurate. <br /> UST Service Technician Signature j <br /> 0--M=raitfnn,ia R,vtmrc►wvW Rarvvftnn S1,dw„ in=kian firarim trr._rrftma inial r via r u ur1l Y=vac N=Nn Ne=wv annru*Ja <br />