My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRANK WEST
>
120
>
2300 - Underground Storage Tank Program
>
PR0515365
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/11/2023 3:49:34 PM
Creation date
7/16/2020 12:59:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0515365
PE
2361
FACILITY_ID
FA0012107
FACILITY_NAME
A TEICHERT & SON INC*
STREET_NUMBER
120
STREET_NAME
FRANK WEST
STREET_TYPE
CIR
City
STOCKTON
Zip
95206
APN
19342006
CURRENT_STATUS
01
SITE_LOCATION
120 FRANK WEST CIR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Afford- a -test <br /> Secondary Containment/SB989 (209) 744-0112 <br /> Line/Leak Detectors <br /> Tank Monitor Certification <br /> Air Quality Testing r <br /> Overfill Prevention/Drop Tube Testing <br /> California UST Service Technicians <br /> California UST Designated Operators <br /> SWRCB Tank Testing License <br /> CSLB License #341375 }} gg <br /> TH <br /> Secondary Containment Test Procedure Used To Determine Test Results <br /> Tank Secondary Containment — The Service Technician will test and certify using <br /> methods developed and recommended by the Tank Manufacture, Industry Standard or <br /> Professional Engineer . Test procedure recommended and used is a vacuum slowly <br /> applied to establish a stable vacuum of 6" to 10 " inches Hg. for one hour using a <br /> Standard Industry Vacuum Gauge with a range of 4 ' to -30 " measured in Hg./inches of <br /> mercury . The test is completed at the end of one hour/Tanks with a Volume of 20 , 000 <br /> Gallons or less , and 2 hours for Tanks that exceed a Volume of 20 , 000 Gallons , if the <br /> vacuum reading does not decrease below the established vacuum or the Threshold <br /> Criteria recommended by the Tank Manufacture , Industry Standard, or Professional <br /> Engineer. <br /> Product Piping Containment/Vent Piping Containment/Vapor Recovery Piping <br /> Containment — The Service Technician will test and certify using methods developed <br /> and recommended by the Piping Manufacture, Bravo System UDC Manufacture, Industry <br /> Standard or Professional Engineer. Test procedure recommended and used is , Nitrogen <br /> Gas pressure, slowly applied to establish a stable pressure of 5 psi for one hour or 3 Psi <br /> for 1 hour using a Standard Industry Pressure Gauge with a range of 0 to 15 measured in <br /> Psi/Pounds per square inch . If the Product Piping is Fiberglass and the UDC ' s are a <br /> Bravo System Manufacture, constructed of Coated Steel , with an O Ring Seal at <br /> Primary/Secondary Product Piping Interface at end of Product Piping Run at UDC ' s then, <br /> Bravo System Manufacture recommends a maximum applied test pressure of 3 Psi . The <br /> test is completed at the end of one hour if the pressure reading does not decrease below <br /> the established pressure or the Threshold Criteria recommended by the Piping <br /> Manufacture, Bravo System UDC Manufacture , Industry Standard or Professional <br /> Engineer. <br /> Turbine/Product Piping Sump/Fill Riser Sump/Remote Fill Sump/Transition/Vent <br /> Sump/Spill Container/Misc . Sump connected to UST System — The Service <br /> Technician will test and certify using methods developed and recommended by the Sump <br /> Manufacture, Industry Standard or Professional Engineer . The test procedure <br /> recommended and used is Hydrostatic with a level change indicator that has been <br /> developed to indicate a standard leak rate of I/4 inch in 24 hours within 30 minutes , and <br />
The URL can be used to link to this page
Your browser does not support the video tag.