Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> MONITORING SYSTEM CERTIFICATION FORM (Page 1 of 6) <br /> This form must be used to document testing and servicing of underground storage tank ( UST) monitoring equipment. A copy <br /> of this form must be provided to the UST owner or operator. The owner or operator must submit a copy of this form to the local <br /> agency regulating the USTs within 30 days of the date of the monitoring system certification . <br /> I . FACILITY INFORMATION <br /> CERS ID Date of Monitoring System Certification <br /> Unknown 9/ 16/2020 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) Building # <br /> Stockton Teichert Mobile Equipment <br /> Business Site Address City ZIP Code <br /> 120 Frank Circle I Stockton 195206 <br /> II . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of Company Performing the Certification Phone # <br /> Walton Engineering , Inc . (916 ) 372- 1888 <br /> Mailing Address <br /> P . O . Box 1025 , West Sacramento , CA 95691 <br /> Name of UST Service Technician Performing the Certification (Print as shown on the ICC Certification) <br /> Curtis Carpenter <br /> Contractor / Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> 617238 8167865 5/ 14/2022 <br /> Monitoring System Training and Certifications List all applicable certifications. Expiration Date <br /> Veeder- Root 12/4/2020 <br /> Va orless - VMI 2/4/2021 <br /> 111 . RESULTS OF TESTING / SERVICING <br /> Indicate and attach the following reports if the monitoring equipment is capable of generating either. Y N NA <br /> Monitoring System Set-up Alarm History Report <br /> Was any monitoring equipment replaced? ❑ N 1:1 <br /> (If "Yes, " identify the specific devices replaced and list the manufacturer and model for all replacement parts in section IV below) <br /> Was damage , debris , or liquid found inside any secondary containment systems? ❑X El <br /> El <br /> (If "Yes, " describe what was found in section IV below.) <br /> Is all monitoring equipment operational per manufacturer' s specifications? FX] E1 E <br /> (If No, " describe why in section IV below) <br /> IV. COMMENTS <br /> If directed to use this section, describe how and when the issues were or will be corrected. <br /> A small amount of water was removed from the 87 STP sump . <br /> V. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> I hereby certify that the equipment identified in this document was inspected/serviced in accordance with California Code of <br /> Regulations , Title 23 , Division 3, Chapter 16 , Section 2638 and all information contained herein is true and accurate . Attached to <br /> this certification is information (e. g . , manufacturers ' checklists , monitoring system set-up, alarm history report, etc .) necessary <br /> to verify that this information and the site plan showing the layout of UST system is complete and accurate . <br /> UST Service Technician Signature /�) <br /> CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council, Y = Yes, N = No, NA = Not Applicable <br />