My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1234
>
2300 - Underground Storage Tank Program
>
PR0516248
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2020 7:52:05 AM
Creation date
7/16/2020 1:06:07 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0516248
PE
2361
FACILITY_ID
FA0012532
FACILITY_NAME
CHEVRON STATION #209167
STREET_NUMBER
1234
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22120016
CURRENT_STATUS
01
SITE_LOCATION
1234 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
106
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> MONITORING SYSTEM CERTIFICATION FORM (Page 4 of 6) <br /> VIII. MONITORING SYSTEM AND PROGRAMMING <br /> This section must be com leted if a monitoring panel is used to perform leak detection monitoring , Y N NA <br /> Are the visual and audible alarms operational ? r <br /> Were all sensors visually inspected for kinks and breaks in the cables and for residual buildup to ensure that floats (— <br /> move freely , functionally tested , and confirmed operational? <br /> Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not r �- <br /> interfere with their proper operation ? <br /> Iv r r <br /> Was monitoring system set-up reviewed to ensure proper settings? <br /> Was the monitoring panel's backup battery visually inspected , functionally tested , and confirmed operational? r r r <br /> Does the flow of fuel stop at the dispenser if a leak is detected in the under-dispenser containment? ''� r <br /> Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is I- (— <br /> electrically disconnected? <br /> Does the turbine automatically shut down if the piping secondary containment monitoring system detects a leak? r r <br /> Which sensors initiate positive shut down? Check all that apply ,) W Sump W Under-dispenser containment <br /> If alarms are relayed to a remote monitoring station , is all communications equipment (e . g . modem)) operational ? <br /> For any answer of "N " above, describe in section IX how and when these deficiencies were or will be corrected. <br /> IX COMMENTS <br /> Use this section to provide any additional comments about the inventory of the equipment certified. <br /> f ° g ` [ <br /> ply <br /> X IN TANK GAUGING TESTING <br /> Check this box if tank gauging is used only for inventory control . (Do not complete this section.) Y N NA <br /> r Check this box if NO tank gauging equipment is installed . (Do not complete this section .) <br /> This section must be completed if in-tank gauging is used to perform leak detection monitoring. <br /> Has all input wiring been inspected for kinks and breaks in the cables and for proper entry and termination , including r r <br /> testing for ground faults? <br /> Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely , r r <br /> functionally tested , and confirmed operational? <br /> Was accuracy of system 's product level readings tested ? r <br /> Was accuracy of system' s water level readings tested? r <br /> Were all probes reinstalled properly? r <br /> Were all items on the equipment manufacturer' s maintenance checklist completed ? r r r <br /> For any answer of W' above, describe in section XI how and when these deficiencies were or will be corrected. <br /> XI . COMMENTS <br /> Use this section to provide any additional comments about the inventory of the equipment certified. <br /> EXTERNAL ALARM WAS NOT WOKING RITE WHEN TESTING PROBES , <br /> BUT WAS WORKING ON VEEDER ROOT. <br /> Y = Yes , N = No, NA = Not Applicable <br />
The URL can be used to link to this page
Your browser does not support the video tag.