My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1234
>
2300 - Underground Storage Tank Program
>
PR0516248
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2020 7:52:05 AM
Creation date
7/16/2020 1:06:07 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0516248
PE
2361
FACILITY_ID
FA0012532
FACILITY_NAME
CHEVRON STATION #209167
STREET_NUMBER
1234
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22120016
CURRENT_STATUS
01
SITE_LOCATION
1234 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
106
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 2 of 2 <br /> 2 . SECONDARY PIPE TESTING <br /> Test Method Developed By : ❑ Piping Manufacturer ® Industry Standard ❑ Professional Engineer <br /> ❑ Other (Spec) <br /> Test Method Used : ® Pressure ❑ Vacuum ❑ Hydrostatic <br /> ❑ Other (Spec) <br /> Test Equipment Used : See attached testing procedures Equipment Resolution : <br /> Piping Run # 87 Piping Run # 91 Piping Run # Piping Run # <br /> Piping Material : Fiberglass Fiberglass <br /> Piping Manufacturer: Smith Smith <br /> Piping Diameter : 3 " 3 " <br /> Length of Piping Run : Approx 200 ' Approx 200 ' <br /> Product Stored : Regular Premium <br /> Method and location of Test boot in Sump Test boot in Sump <br /> piping-run isolation : <br /> Wait time between applying 30 minutes 30 minutes <br /> pressure/vacuum/water and <br /> startin test: <br /> Test Start Time : Visual Failure 9 : 05am <br /> Initial Reading (Ri) : 5 PSI 5 PSI <br /> Test End Time : 10 : 05am <br /> Final Reading (RF) : 5 PSI 5 PSI <br /> Test Duration : 1 hour 1 hour <br /> Change in Reading (RF-RI) : 0 0 <br /> Pass/Fail Threshold or 0 . 00 0 . 00 <br /> Criteria: <br /> Test Result: ❑ Pass ® Fail ® Pass ❑ Fail `+ ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> Comments — (inchide information on repairs made prior to testing, and recommended follow-zrp for•failed tests) <br /> 87 Prod Sec Line - Visual Failure <br /> i <br /> i <br />