My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAM
>
1331
>
2300 - Underground Storage Tank Program
>
PR0231332
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2020 3:26:56 PM
Creation date
7/16/2020 3:06:23 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231332
PE
2361
FACILITY_ID
FA0003961
FACILITY_NAME
LODI MUNI SERVICE CENTER
STREET_NUMBER
1331
Direction
S
STREET_NAME
HAM
STREET_TYPE
LN
City
LODI
Zip
95242
APN
03104050
CURRENT_STATUS
01
SITE_LOCATION
1331 S HAM LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
107
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECEIVED <br /> � <br /> nr 1 3 207. 0 <br /> SAN J O A Q U I N ENVIRONMENTAL HEALTH <br /> Environmental Health Department <br /> I.) FPAR T v1IENT AMENDED <br /> 9/16/2020 <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name : Facility Address : Date : <br /> LODI MUNI SERVICE CENTER 1331 S HAM LN , LODI September 16 , 2020 <br /> File Review <br /> 122 CCR 2631 , 2640, 1 , Failure to submit and/or maintain documentation regarding compatibility for UST system components o V o R o COS <br /> 2665 , 2711 <br /> 123 CCR 2637. 1 (d) , Failure to submit the "Spill Container Testing Report Form" within 30 days after the test o V o R o COS <br /> 2637. 1 (e) <br /> 124 CCR 2637 ,2(d&e), "Overfill Prevention Equipment Inspection Report Form" not submitted within 30 days of inspection o V o R ❑ COS <br /> 2665(a&b) <br /> On Site Records <br /> 201 CCR 2712(b)( 1 -2) Failure to maintain monitoring, maintenance, and follow up action records ❑ V o R in COS <br /> 202 CCR 2715(c)(3), Failure to maintain the "Facility Employee Training Certificate" on-site (after October 1 , 2018 ) ❑ V ❑ R ❑ COS <br /> 2715 (c) 4 <br /> 203 CCR 2712(b)(6) Failure to maintain records of repairs, lining, and upgrades on site, for the life of the UST o V ❑ R o COS <br /> 204 CCR 2712(i) Current monitoring plan approved by the EHD not found on site ❑ V n R o COS <br /> 205 CCR 2712(1), 2634 (e ) Failure to submit a current UST Response Plan and have it available onsite ❑ V o R o COS <br /> 206 CCR 2712 Failure to comply with UST operating permit conditions o V ❑ R o COS <br /> 207 HSC 25294 Failed to record unauthorized release from primary containment n V ❑ R o COS <br /> 208 CCR 2650 (e), 2652 Failed to notify the EHD of a reportable unauthorized release and/or prepare a report o V n R ❑ COS <br /> 209 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days ■ V ■ R o COS <br /> 210 CCR 2716(f) DO monthly reports not maintained on site for 12 months or for 36 months (after October 1 , 2018) o V ❑ R o COS <br /> 211 CCR 2715(c)(2 ) No employee present that were trained in the operation and maintenance of the UST system by a DO o V ❑ R ❑ COS <br /> 212 CCR 2715(c)(2) Unstaffed facility failed to have or implement a training program approved by the UPA ❑ V o R o COS <br /> 213 HSC 25281 .5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily or log not kept o V ❑ R o COS <br /> 214 HSC 25281 .5(b)(3) Unburied emergency generator fuel piping not visually inspected at least monthly or log kept ❑ V o R ❑ COS <br /> 215 CCR 2712(i) Failure to retain a copy of the permit to operate at the facility o V ❑ R o COS <br /> UST System Observations <br /> 301 HSC 25292. 1 (a) UST system Is not operated to prevent unauthorized release, including spills and overfills o V o R o COS <br /> 302 HSC 25291 (b) UST system incapable of detecting leak from primary into secondary containment (pre-Jul 2003) ❑ V in R o COS <br /> 303 HSC 25290 ,2(d) Monitoring system not maintained to detect entry into secondary containment (Jul 2003-Jun 2004) o V ❑ R ❑ COS <br /> 304 HSC 25290 . 1 (d) Monitoring system not maintained to detect entry into secondary containment (after Jul 2004) o V ❑ R ❑ COS <br /> 305 HSC 25290. 1 (e) VPH monitoring of the interstitial spaces of the UST system is not maintained n V ❑ R o COS <br /> 306 CCR 2630(d) , 2641 (a) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity ■ V o R o COS <br /> 307 CCR 2631 (g) , 2632(c) Monitoring system of the interstitial space of a double walled system not maintained o V o R o COS <br /> 308 CCR 2632(c) , 2634(d), Failed to maintain a continuous monitoring system that activates an audible and visual alarm o V o R o COS <br /> 2636(f) <br /> 309 CCR 2636(f)( 1 ) Monitoring in sump / UDC failed to activate an audible and visual alarm or stop the flow product o V o R o COS <br /> 310 CCR 2636(f)(4) Piping is not fail-safe outside UDCs or fails to stop flow of product at dispenser Inside UDCs ❑ V o R o COS <br /> 311 CCR 2638(a ), 26410) Failed to properly program , calibrate , operate, or maintain leak detection equipment ❑ V o R o COS <br /> 312 CCR 2638 (f), 2641 (1) Failed to affix a tag sticker on monitoring equipment certified , repaired, or replaced ❑ V o R o COS <br /> FA0003961 PR0231332 SCO01 09/16/2020 <br /> EHD 23-01 Rev, 9/16/2020 Mage 2 Of 5 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 1 F 209 464 -0138 I www. sjgov . org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.